ALTITUDE™ X 36 DIRECT VENT GAS FIREPLACE
Product information provided is not complete and is subject to change without notice. Please consult the installation manual for
the most up to date installation information.
Wall Penetration
1" [25mm] minimum all sides for vertical venting sections.
When passing through a ceiling, use firestop
W500-0028 (not supplied).
Non-combustible
material
11"
[279.4mm]
72" (182.8cm)
min. for typical application
84" (213cm) min.
for recess application
34 13/16"
(88.4cm)
Flush & Recessed Framing
Flush Framing
72"
(182.8cm)
min.
11"
(28cm)
35 3/4"
(90.8cm)
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada •
Combustible
Non-combustible
Brick
3"
[76mm]
to top
3"
min.
Insulated
sleeve
2"
[51mm] to
sides / bottom
assembly
1" [25mm]
42 5/8"
(108.2cm)
19"
(48.3cm)
Indicates non-combustible material (supplied).
0" [0mm] if non-combustible
finishing material is used
such as brick and stone.
note:
Vent Sections
When passing through a wall, use
fi restop spacer W010-1800 (supplied).
When passing through a ceiling,
use fi restop spacer W500-0028 (not
supplied).
Firestop
Horizontal vent sections: A minimum
clearance of 3" (76mm) on the top of the
54 7/8"
(139.3cm)
vent to combustibles and 2" (51mm) on the
plus rise
sides and bottom of the vent to combus-
tibles is required.
Vertical vent sections: A minimum clear-
ance of 1" (25mm) all around the vent
pipe on all vertical runs to combustibles is
required.
Recess Framing
84"
(213cm)
min.
11"
(28cm)
35 3/4"
(90.8cm)
* 2" x 4" frame can be "backed by 3/4"
ply to support TV mounting hardware.
1(866)820-8686
3 1/2"
(89mm)*
42 5/8"
(108.2cm)
19"
(48.3cm)
Indicates non-combustible material (supplied).
W415-1931 / 05.17.19
•