Technical Specification - Parker LDC Serie Manuel D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Catalogue HY10-6005-UM/EU

Technical specification

Technical specification
Cooler matrix
Maximum static working pressure
Maximum dynamic working pressure (Tested according to ISO/DIS 10771-1)
Heat transfer allowance
Maximum oil temperature
Maximum cooling capacity (LDC-033)
Fluid compatibility
Mineral oil (according to DIN 51524)
Oil/water emulsion (according to CETOP RP 77H)
Water glycol (according to CETOP RP 77H)
Phosfatester (according to CETOP RP 77H)
For operation with other fluids or operation under extreme conditions, always consult Parker
Material
Cooler matrix
Fan housing
Fan blades/hub
Fan guard
Surface treatment (fan housing and cooler matrix)
DC-motor
LDC
Speed (rpm))
Protection std.
Insulation class
Ambient temp.
Power consump.
(A) 12V
(A) 24V
* = LDC 023 and LDC 033 have two motors
Use a relay if the current load is superior to 8 A at 12V and 6 A at 24V
For long motor life, make sure that:
- max. ripple voltage of the supply current is 1 %
- max. nominal supply current is ± 10% of 12V and 24V.
002
3700
IP 68
H
6.5
3.5
Installation and servicing manual
Air Oil Coolers, LDC
003
004
3670
3350
IP 68
IP 68
H
H
–30 °C - +80 °C
8
8
4
4
13
Electrostatic powder coated
007-020
023-033
3060
3060
IP 68
IP 68
H
H
20
2x20*
10
2x10*
Parker Hannifin Corporation
Hydraulics Group
21 bar
14 bar
± 6 %
120 °C
30 kW
HL/HLP
HFA, HFB
HFC
HFD-R
Aluminium
Steel
Plastic
Plastic

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ldc 002Ldc 003Ldc 004Ldc 007Ldc 020Ldc 023 ... Afficher tout

Table des Matières