For the new Bright Control PRO II we could win a renowned European manuf-
acturer as development and production partner. Thanks to an intelligent chip
control an increased life of the ballast and optimal operation of the Bright
Sun is ensured. In addition we could fulfil the wish of several consumers to
be able to operate more than one wattage with one ballast to gain more
flexibility. Over a switch it is now possible to select two different wattages.
A lamp socket is not included. We recommend the use of a Lucky Reptile Plug
and Play luminaire of which different models are available.
Choosing the wattage
Attention: The wattage can be selected over a switch on the front
of the device. The lower wattage is always selected by the lower
switch position. Make sure that the selection corresponds to the
wattage of the used lamp. Changing the wattage must only be
done of the lamp is disconnected from power supply!
Installation using Lucky Reptile Plug and Play lumi-
naires
Install the Plug and Play luminaire as described in its manual. Plug the con-
nector (male) of the Plug and Play luminaire into the female connector of the
Bright Control ballast. Potentially available power cables of the Plug and
Play luminaire are not needed.
Screw the Bright Sun UV lamp into the socket. Make sure that it is fitting
properly and has good contact to the electrical parts of the socket.
Plug the Bright Control PRO II into the wall socket. The lamp should now
ignite and rise continually in brightness. If the ignition phase takes a long
time or ignition is not possible, check if the lamp is correctly screwed into
the socket.
Installation of other lampholders and luminaires must only be done by a
professional electrician. It is the responsibility of the user to check if such a
combination is permitted and the product safety is maintained. Please note
that only a few lampholders are suitable for use with metal halide lamps. It
is best to attach other luminaries by using the connector system. Compatible
male connectors are available separately.
Operating conditions
•It has to be ensured that the device cannot fall into water.
•Secure the device with screws in the destined holes against movement and
accidental drops.
•The ambient temperature limit during operation may not fall below and
exceed -25°C and 45°C respectively.
•The device is designed for use in dry and clean rooms.
Manual
50 W
70 W
35 W
35 W
•At formation of condensed water a period of acclimatisation of up to 2h
has to be ensured.
•Protect the device from moisture, spray water and impact of heat!
•The distance between ballast and lamp may not exceed 3m.
Important Information:
• Do not undertake any modification and do not open the case.
• Device and sensor cords have to be checked always for signs of damage.
If a defect is discovered the device has to be put out of operation imme-
diately. The same applies if the device has come into contact with fluids.
• Generally it should be verified if the device is applicable for the application
at hand before putting it into operation!
• In case of doubt consultation of experts or the manufacturer of the emplo-
yed devices is required.
• The device is designed for use with metal halide lamps. Make sure that the
correct wattage is used. Ensure that no other lamp types are used.
• The device has to be installed in a way that it cannot be touched during
operation.
• Only touch the device if disconnected from main power supply.
• The device gets hot during operation!
• Before lamp change the device has to be disconnected from power supply!
• The ballast needs to be disconnected from the power supply if the wattage
is supposed to be changed over the switch. During operation the switch
must not be changed!
• During ignition phase voltages of approx. 5 kV can occur.
• If the lamp does not ignite that device will power down and will retry igni-
tion after 1-2 minutes.
Warranty
The warranty expires in case of modification and repair attempts as well as
damaging by force or inappropriate usage.
Neither a guarantee nor any liabilities for detriments or consequential da-
mages in relation with this product will be assumed.
In case of warranty claims or repairs contact your specialist dea-
ler.
Technical Data
Voltage:
Max. Ignition Tension Uotw (peak)
Max. Operating Temperature tc
Ambient Temperature ta
200-250 V~ 50/60 Hz
3,8 - 5 kV
80°C max.
-25° bis +45°C