AC VOLTS
Range
Resolution Accuracy
400mV
100µV
4V
1mV
40V
10mV
400V
1V
600V
Input impedance: 10MΩ for all ranges.
Frequency response: 50 - 400Hz
RESISTANCE (OHMS)
Range
Resolution Accuracy
400Ω
0.1Ω
4kΩ
1Ω
40kΩ
10Ω
400kΩ
100Ω
4MΩ
10kΩ
40MΩ
DC CURRENT (AMPS)
Range
Resolution Accuracy
40mA
10µA
400mA
100µA
*15A
10mA
*A waiting period of at least 15 min utes is necessary between
every 15 second testing period.
5
±(1.2% of
250V DC RMS
reading
+8 digits)
±(0.8% of
reading
+ 8 digits)
600V DC/AC RMS
±(1.2% of
reading
+ 8 digits)
±(1.0% of
reading
+ 5 digits)
250V DC/AC
±(2.0% of
reading
+ 5 digits)
±(1.5% of 0.5A/250V fast fuse
reading
(Input Voltage
+ 5 digits) Drop: <0.2V.
±(2.5% of
Unfused; 15sec maximum
reading
Input Voltage Drop: <0.2V.
+ 5 digits)
Overload Protection
Overload Protection
Overload Protection