Operating Instructions
Introduction
The Quickset is the beginner model in the class of fully
automatic rotation lasers with visible beam for all horizontal
applications. The instrument makes no compromise with
respect to accuracy and performance.
Its functional control panel guarantees easy handling for various
measuring tasks at indoor and outdoor applications.
Prior to shipment all instruments are carefully checked.
Read the complete Operating Instructions including the
Technical Data and the Safety Requirements prior to using the
equipment the first time.
We recommend you to observe the following items so that your
laser is ready for use at all times:
1.
Never place the instrument in its case when wet.
2.
Check the accuracy each time before using the instrument,
as we cannot assume any responsibility for adjustment
errors.
3.
Follow the instructions for handling the accu.
4.
Treat the laser beam window and sensor window of the
receiver (option) with care.
2. Preparations for measurement
Set up the Quickset on a solid, even ground or screw it on tight on a tripod.
Align the tripod within the range of < 5° and press key (4) to activate the
instrument. The operating indicator (3) lights up and the out of level indicator (2)
is blinking.
If the tripod head was tilted more than 5°, this will be indicated after a brief period
of time by rapid flashing of the laser beam and the out of level indicator (2).
Should this occur, shut off the instrument and align the tripod more carefully.
As soon as the laser levelling process has been finished, the laser beam starts
rotating and the out of level indicator expires.
3. TILT function
Should major height changes occur (e.g. an inadvertent jerk of the tripod leg), a so
called Tilt function effects a shutdown of the laser beam even within the
automatic levelling range, and this occurrence is signalled by rapid flashing of the
laser beam and the out of level indicator (2).
The instrument has to be readjusted and switched on.
UK
11
13
1. Operating elements / Display
(1)
(2)
(3)
(4)
(1)
Laser exit
(2)
Out of level indicator
(3)
Operation indicator
(4)
Button On/Off
(5)
Accu condition indicator
(6)
Accu compartment with charging socket on the back
4. Power supply
4.1 Laser
As soon as the accu condition indicator (5) blinks, the capacity of the
accumulator is exhausted and the accu has to be recharged immediately. If the
indicator is ignored, the instrument switches off automatically a short time later.
Recharging of the accumulator only with THEIS standard-charger via charging
socket (6) at the accu compartment of the laser level. The accu can also be
charged, if the accu compartment is separated from the laser level.
Overloading is not possible, if charging is not repeated successive several times.
If possible the accu should be charged at room temperature. Charging under
+5°C can cause the damage of the accu.
Never operate charger in damp rooms!
Please charge the instrument at least every 6 weeks, even it is not
used!!!
4.2 Receiver
When the battery symbol (18) appears on the LCD-display, change the battery
(9V, E-Block), otherwise the range may be reduced.
Press sliding cover of battery section slightly, then push it sideways open.
Dispose old batteries properly. Watch for the right polarity when inserting the
new batteries. (Pay attention to symbols at the receiver case)