12
| English
a detergent, the detergent intake circuit must be
flushed out with clean water.
NOTE
Detergent must only be delivered in the low-pres-
sure setting.
1. Prepare the solution of detergent at the con-
centration most suitable for the type of dirt
and the surface that is to be washed.
2. Activate the detergent suction control on the
lance (low pressure), operate the water cleaner
and spray the surface to be washed, starting
from the bottom and working upwards.
3. Rinse the whole surface well from top to bot-
tom with hot or cold water at high pressure.
4. After use with detergent, flush out the intake
circuit by placing the detergent suction hose in
a tank of clean water and letting the pump run
for 1 minute with the dosing tap turned fully on
and the lance in detergent delivery condition.
Stopping the machine
1. Turn the burner off by rotating the pressure reg-
ulator to the "0" position.
2. Let the pressure washer run with cold water only
for at least 30 seconds to cool down the boiler.
3. Stop the pressure washer by turning the "On-
Off" switch to pos. "0".
4. Discharge the pressure from the high pressure
hose by pressing the trigger on the gun.
5. Disconnect the machine from the mains electric-
ity supply.
6. Turn off the water supply tap.
WARNING
Dry use of the water cleaner causes serious damage
to pump gaskets. If the pressure washer is left, even
temporarily, turn it off by using the switch or by un-
plugging the plug from the socket.
PRECAUTIONS AGAINST FROST
The cleaner must not be exposed to frost. If the
machine is left in premises where it is exposed to
frost, when work is over or for storage, antifreeze
must be used to prevent serious damage to the
hydraulic circuit:
1. Turn off the water supply, disconnect the hose
and run the cleaner until it is completely empty.
2. Stop the machine with the "On-Off" switch in
the "O" position.
3. Prepare a container with the solution of anti-
freeze.
4. Immerse the tube in the container with the an-
ti-freeze solution (Fig. 13).
5. Start the machine with the "On-Off" switch in
the "I" position.
6. Let it run until antifreeze comes out through
the lance.
7. Suck up antifreeze with the detergent intake
system too.
8. Disconnect the machine from the mains elec-
tricity supply.
NOTE
For high pressure cleaners provided with water tank,
the detergent solution prepared must be poured di-
rectly into the water tank.
PWH 130 PRO | PWH 170 PRO
NOTE
Anti-freeze may cause environmental pollution. Al-
ways follow the instructions given on the pack.
MAINTENANCE AND CLEANING
WARNING
Disconnect the machine from the mains electricity
supply and close the water supply tap before carry-
ing out any maintenance jobs. Once maintenance has
been completed, ensure that the closing panels have
been correctly reassembled and anchored with the
screws provided before reconnecting the machine
to the mains.
MAINTENANCE SCHEDULE
Frequency
Items
Complete
Visual
√
unit
Ispection
Control
√
Check
handles
Power
√*
Check
cables
√*
Pipes
Check
High
pressure
√*
Check
connec-
tions
Check-
Fuel fiter
Clean
Check-
Water filter
Clean
Fuel tank
Clean
Clean
Boiler coil
Descale
Pump oil
Change
and seals
Fuel pump
Clean
Fuel nozle
Change
Regulate
Electrodes
Change
Check
√
Safety
devices
Calibrate
Lance
Change
nozzle
*These items should be replaced if needed.
**These components should be serviced and repaired only
by authorized service center, that have the proper tools and