Télécharger Imprimer la page

Franke KEPAC-EB Serie Manuel D'installation page 9

Publicité

Les langues disponibles

Les langues disponibles

SECTION 3: CONNECTING THE WATER LINE
DRINKING FOUNTAIN
B. RETROFIT or FOUNTAIN/FRAME (PRESSURIZED COOLING TANK)
a)
Disconnect power by UNPLUGGING unit. It might be necessary to remove the front panel to get access to the power.
b) Turn OFF water supply to the unit. It might be necessary to remove the front panel to access the water stop valve.
c)
Place hole template onto cooler top so it is aligned with the left side of unit and wall. SEE NEXT PAGE FOR TEMPLATE.
d) Mark hole location.
Mark hole location
Template
e) Remove top from unit. (Figure 1)
f)
Using a step drill bit OR 7/8" punch die, make a 7/8" hole through top. You may want to drill a pilot hole to get these started.
g)
Install snap bushing into hole to protect tubing from being cut. (Figure 2)
11/16 2030003743
Figure 1
Remove top from cooler by
removing six #15 torx head
screws on sides of top.
Drill
Figure 2
Install Bushing
9