Hayward Pool ColorLogic Guide De L'utilisateur page 6

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Fitting instructions for wooden panel/liner or fiber panel/liner swimming pools
1. Make the cutout in the panel on the basis of an outside size of a maximum of 310 mm and of a minimum of 303 mm (about 3 mm larger than the
outside size of the rear ring).
2. Place the rear ring in the cutout from the rear of the panel and fasten with six wood screws of suitable length (screws not supplied).
3. Feed the niche through the panel from the inside of the pool (metal insert upwards).
4. Line up the mounting screw holes above and below the niche, and the mounting screw holes in the rear ring, and fasten the resulting assembly
together with the two self-tapping screws SPX1039Z1.
5. Line up the holes in the seal and in the niche. Fasten the seal with a little adhesive (the two larger holes are positioned over the two mounting screw heads).
6. Install the liner.
7. Line up the second seal and the front face. Fasten the resulting assembly together with ten self-tapping screws SPX0507Z1A. Ensure that the
setbacks provided in the front face are placed over the heads of the mounting screws. Pierce the liner through the holes in the front face before
engaging the screws.
8. Cut the liner along the bottom portion of the front face.
1. Cement the special niche (SP0536) flush with the finished surface.
2. The sealing is then provided by the cementing of the part and by the product used.
3. Position the lighting fixture in the niche and tighten the two screws of the SP0524PAK.
Fig. II
Ten holes spaced apart
by 36°
Cutout for steel or fiber panels.
1. Circular cutout of 272 mm MAX and 270 mm MIN.
2. Drill or pierce 10 holes of 8 mm (5/16") in diameter, spaced apart by 36° and lying on a circle of 287.5 mm.
3. Drill or pierce 2 holes of 6 mm (1/4") in diameter, spaced apart by 180° and lying on a circle of 287.5 mm.
Feed the power cable through the stuffing box of the niche and pull it to the junction box. DO NOT CUT EXCESS CORD. Connect the cable of the light to the power
cable in the junction box (Ref. 3495ECO). If there is more than one light, connect them to the same power cable so that they can be synchronized. Wind the cable
around the light and place the resulting assembly into the niche, taking care to keep the mounting screw "at 12 o'clock". Slide the retaining screw situated at the bot-
tom of the niche into the recess provided in the front face and ensure that it is properly engaged. Fasten the resulting assembly together by screwing the top and bot-
tom screws into their recesses. In order to remove the light from the niche, unscrew the bottom and top screws, and then lift and remove the light.
The ColorLogic light is designed to be installed in Eurolite light niches (SP0508 for a liner and SP0536 for concrete).
The ColorLogic light can thus replace a 300 W Hayward Eurolite light (SP0512LINER or SP0512CONCRETE).
The installation of this product must respect the requirements of the CEI 60364-7-702
Fitting instructions for linerless concrete swimming pools
Two 6-mm diameter holes
spaced apart by 180°
272 mm MAX
320 mm O.D.
Fitting the light (IP 68 at 1m)
Liner
SPX0507Z1A
Ten flange mounting screws
SPX0507A1
Front mounting ring
SPX0506DE
Niche seal
SPX1039Z1
Two niche mounting screws
Wooden swimming pool
Steel panel
SPX0507D
Rear ring
SPX0524CKIT
Nut + stuffing box
seal

Publicité

Table des Matières
loading

Table des Matières