RECESSED INSTALLATION ON LOW WALLS
Construct the low walls keeping in mind that the
internal volume measurements referred to in the
technical information sheet are purely approximate.
For ordinary maintenance and for adequate system
ventilation an inspection grill must be mounted on
the low walls near the electric pump, measuring
60x45 cm (code T260000White; code T2600AA
Chromed code T260067 Can be tiled) composed
of the external grill and a steel frame which must
cemented to the structure of the low walls where
the edges of the tub rest by means of appropri-
ate clamps.
The positions for this inspection grill are on the
short side or on the long side but in any case
near the electric pump. The construction of the
low wall must in no way prevent the tub from
being extracted for special maintenance or for
replacement.
4
2
5
256
256
TT0283660_05_PREMIUM_CMYK.indd 256
Before attaching the grill, it is necessary to connect
the frame to the equipotential wire by means of
the appropriate terminal.
1
3
Fig.6