current standards and certified by the CE directive
up to the TH400 connector (Fig. 3).
The power cable must not be less than type H05VV-
F tripolar with a section of at least 1.5 mm
To connect the power cable to the TH400 con-
nector remove "A" and "B" (1), loosen "C" (2) and
push pump cable "D" outwards so the terminal
comes out (3). Insert the power cable "E" through
"A" and "B" by connecting the conductors to the
terminals L, N and
connections, put the terminal back in place, and
tighten "B", "C" and "A".
B
1
A
E
TT0283660_05_PREMIUM_CMYK.indd 253
.
2
(4). Upon completion of
2
D
C
3
4
L
L
N
N
fig.3
e
quIPotentIal connectIon
The whirlpool tub must be connected to the equi-
potential system of the building by a cable with a
section of 2,5÷6mm
2
. Connection is performed by
means of the terminal marked with
the metallic support (fig.4).
, located on
230 V 50 Hz
220 V 60 Hz
fig.4
253
253
28/03/11 16.07