- if, during operation, an insufficient level of water
is detected in the tub.
If the time limit has expired and a function is still
active, the light is not turned off but rather adheres
to the status of the function. This may occur if the
light is turned on without any functions being
active, and subsequently (within 10 minutes) the
whirlpool is activated, for example. If, in the same
start-up conditions, one or more functions are
switched on and off within 10 minutes, the time
limit for shutdown remains in effect.
HYGIENE FUNCTION
(activates the pump for tub disinfec-
tion)
Meaning of LED status
Phase
Disinfection request
Hygiene operation
Whirlpool operation
WHEN THE HYGIENE KEY IS PRESSED:
- if the water and disinfectant levels are correct,
press the 0/I key within 5 seconds (otherwise
the hygiene LED goes off ) so that the LED for
the 0/I key comes on steady green and the
disinfection cycle starts, which lasts about two
minutes;
- if water level in the tub is insufficient, the disin-
fection cycle will not start;
- if level of disinfectant is insufficient, the disinfec-
tion cycle will not start;
- fill the disinfectant tank (see chapter on filling
with disinfectant);
After this time has expired, the pump stops and
the relative LED goes off. The water in the tub
must be drained.
Note:
The disinfection cycle is to be run with the tub full
and with no one in it.
THE FUNCTION MAY BE TERMINATED (THE LIGHT
LED GOES OFF):
- when the function expiration time is up (2 min-
utes);
TT0283660_05_PREMIUM_CMYK.indd 31
- if, during operation, an insufficient level of water
is detected in the tub.
Meaning of LED status
Phase
Function selection ozone
cycle ON/OFF
Whirlpool operation
WHEN THE OZONE KEY IS PRESSED:
- the ozone generating device is started, which
led
status
disinfectant LED
yellow flashing
THE FUNCTION MAY BE TERMINATED (THE LIGHT LED
disinfectant LED
GOES OFF):
steady yellow
- when the whirlpool function ends;
- by user command, pressing the ozone key;
whirlpool LED
- when the function expiration time is up;
on steady blue
Meaning of LED status
Phase
Airpool operation
WHEN THE AIRPOOL KEY IS PRESSED:
- if no functions are active (0/I LED with steady
- if there are other functions active (0/I LED with
- if the level of water in the tub is insufficient, the
OZONE FUNCTION
3
(only with whirlpool function active)
enriches the air/water mixture with ozone from
the sides jets
AIRPOOL FUNCTION
(activates the blower for the whirlpool,
nozzles on bottom of tub)
red light), press the 0/I key within 5 seconds
(otherwise the blower shuts off ) so that the 0/I
key LED comes on steady green and the blower
starts;
steady green light), the blower starts at 50%
power;
blower will not start (the pipe drying function
does however start for 30 seconds);
led
status
ozone LED steady
blue
whirlpool LED on
steady blue
led
status
airpool LED steady
blue
31