ROBUST - H
Dimensions and installation
Permanently installed fan heater
Portable fan heater
Permanent installation
If the fan heater is permanently installed it must be mounted at least 1800 mm above the floor.
The rail supplied should be secured to the wall by means of screws. Then hook the fan heater to the rail and secure it with
screws at the bottom edge. Check that the fan heater is firmly secured. If the fan heater is permanently installed, an isolating
switch with a contact gap of at least 3 mm must be provided. Check the rating plate of the fan heater and the wiring diagram
on the cover to ensure that the installation has been correctly made. The installation work should be done by authorized per-
sonnel and in accordance with the relevant instructions.