Exemple D'étiquette De Numéro De Série/De Sécurité - Quadra-Fire DISCOVERY-III Manuel Du Propriétaire

Masquer les pouces Voir aussi pour DISCOVERY-III:
Table des Matières

Publicité

Discovery III
REMARQUE : Les dégagements ne peuvent être diminués
que si cela est autorisé par les autorités compétentes.
A. Exemple d'étiquette de numéro de série/de sécurité 
EMPLACEMENT : Arrière de l'appareil
CAUTION
ATTENTION:
APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE
LISTED ROOM HEATER, SOLID FUEL TYPE.
COMBUSTIBLE SOLIDE, POUR USAGE DANS LES
ALSO FOR USE IN MOBILE HOMES. (UM) 84 HUD
MAISONS MOBILES. (UM) 84 HUD. "Pour Usage
PREVENT HOUSE FIRES
Avec Bois Solide Seulement"
Install
and
use
only
in
accordance
with
manufacturer's installation and operating instructions.
Contact local building or fire officials about restrictions
PRÉVENTION DES FEUX DE MAISON
and installation inspections in your area. Do not
obstruct the space beneath heater.
Installez et utilisez en accord avec les instructions
For use only with leg and pedestal options intended
d'installation et d'opération du fabricant. Contactez le bureau
de la construction ou le bureau des incendies au sujet des
for this model, refer to owner's manual for appropriate
restrictions et des inspections d'installation dans votre
part numbers and installation instructions.
voisinage. Ne pas obstruez l'espace en dessous de
WARNING - For Mobile Homes: Do not install in a
l'appareil.
sleeping room. An outside combustion air inlet must be
AVIS - Pour Les Maisons Mobiles: Ne pas installer dans
provided and unrestricted while unit is in use. The
une chambre à coucher. Un tuyau extérieur de combustion
structural integrity of the mobile home floor, ceiling and
d'air doit être installé et ne doit pas être obstrué lorsque
l'appareil est en usage. La structure intégrale du plancher, du
walls must be maintained. The stove needs to be
plafond et des murs de la maison mobile doit être maintenue
properly grounded to the frame of the mobile home.
intacte. L'appareil de chauffage doit être fixé à la charpente
Components required for mobile home installation:
de la maison mobile. Les composants requis pour
Outside Air Kit, Part Number OAK-ACC.
l'installation des maisons mobiles: Assemblage d'air
Refer to manufacturer's instructions and local
extérieur, Numéro de Pièce OAK-ACC.
codes for precautions required for passing chimney
Référez vous aux instructions du fabricant et des codes
locaux pour les précautions requises pour passer une cheminée
through a combustible wall or ceiling and maximum
à travers un mur ou un plafond combustibles, et les
offsets.
compensations maximums.
Inspect and clean chimney frequently - Under Certain
Inspectez et nettoyez la cheminée fréquemment. Sous
Conditions of Use, Creosote Buildup May Occur
certaines conditions, il se peut que la créosote s'accumule
Rapidly.
rapidement.
Ne pas connecter cet appareil à une cheminée servant un
Do not connect this unit to a chimney serving another appliance.
autre appareil.
Optional Components:
Optional Blower, Part
Composants Optionnels: Ventilateur Optionnel, Pièce
812-4900.
812-4900.
Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.
Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.
Route power cord away from unit. Do not route cord
Éloignez le fil électrique de l'appareil. Ne pas faire passer le
under or in front of appliance.
fil électrique au dessus ou en dessous de l'appareil.
8
DANGER: Il y a risque de décharge électrique.
DANGER: Risk of electrical shock. Disconnect
Déconnectez le fil électrique de la prise de contact avant le
power supply before servicing.
service.
Replace glass only with 5mm ceramic available from
Remplacez la vitre seulement avec une vitre céramique de 5
your dealer.
mm disponible chez votre fournisseur.
Do not use grate or elevate fire. Build wood fire
N'élevez pas le feu. Bâtissez le feu de bois directement sur
l'âtre.
directly on hearth.
Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau de
Do not overfire - if heater or chimney connector glows,
cheminée rougissent, vous surchauffez.
you are overfiring.
Opérez l'appareil seulement lorsque la porte de chargement
Operate only with the fuel loading door closed. Open
est fermée. Ouvrez la porte seulement lorsque vous devez
only to add fuel to the fire.
ajouter des combustibles dans le feu.
EMBER PROTECTION
:
PROTECTION DU PLANCHER:
Le protecteur de plancher doit être d'un minimum de 3/8
It is necessary to install a Type I floor protector.
inch (10mm) d'épaisseur de matériel incombustible ou
Floor protector must be non-combustible material,
équivalent, s'étendant du dessous de l'appareil de
extending beneath appliance and to front/sides/rear as
chauffage à l'avant, aux cotés et à l'arrière comme indiqué
indicated
on
the
diagram
below.
Exception:
sur le diagramme suivant. Exception: Les protections
incombustibles du plancher doivent s'étendre en dessous
Non-combustible floor protections must extend beneath the
du conduit de cheminée lorsqu'installées avec une
flue pipe when installed with horizontal venting and extend
ventilation à l'horizontale et s'étendre de 2 inches (51mm)
2 inches (51mm) beyond each side.
de chaque côté.
3-1/4"
4-3/4"
41"
minimum
Fuel loading door
8"
16" from glass
USA
31-5/8" minimum
Flat Top & Step Top
Manufactured by:
Fabriqué par:
352 Mountain House Road, Halifax, PA 17032
www.quadrafire.com
2
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER
:
COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS.
CHAUD LORS DE L' O PÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L' E SPACE DÉSIGNÉ DE L' I NSTALLATION. LE CONTACT PEUT CAUSER DES
BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L' E SPACE DÉSIGNÉ DE L' A PPAREIL. VOIR L' É TIQUETTE ET LES INSTRUCTIONS.
O-T L
Tested and
Listed by
C
OMNI-Test Laboratories, Inc.
Report / Rapport
0061WS067S
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or blued steel connector
pipe, with a listed factory-built UL103HT* Class "A" chimney, suitable for use with solid fuels, or a
masonry chimney, and the referenced clearances.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air insulated connector pipe
with listed factory-built UL103HT* Class "A" chimney, or a masonry chimney and the referenced
clearances
MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DL double
wall connector pipe. Must be equipped with a spark arrestor. Apply double wall clearances below when
installing unit.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
NOTE: All "A" , T"C" and "F" Dimensions are to inside diameter of the flue collar.
INSTALLATION: FULL VERTICAL OR HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP
INSTALLATION: ENTIÈREMENT VERTICALE OU HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
SINGLE WALL PIPE
Flat Top Model
Step Top Model
DOUBLE WALL PIPE
Flat Top Model
Step Top Model
INSTALLATION: 90o ELBOW OFF TOP OF STOVE THROUGH BACKWALL
INSTALLATION: 90 o DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIÈRE
DOUBLE WALL PIPE
Flat Top Model
Step Top Model
INSTALLATION: ALCOVE -
chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48 inches (1219mm)
and the referenced alcove clearances
INSTALLATION: ALCÔVE -
cheminée ou une cheminée de maçonnerie. (Mobile Home doit être équipé d' un pare-étincelles.) Profondeur maximale de Alcove ne doit pas être plus de 48 pouces (1219mm) et les
dégagements en alcôve référencés.
DOUBLE WALL PIPE
Flat Top Model
Step Top Model
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 o C Factory-built chimney.
*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650 o C cheminée bâtit en usine.
203mm (8")
203mm
203mm
90
o
OFF TOP
(8")
(8")
UP & OUT CEILING CLEARANCE
1295mm
ESPACE LIBRE DU DESSUS DE
(51")
L'APPAREIL AU PLAFOND AVEC 90
minimum
DE COURBURE
STOVE TO CEILING CLEARANCE
457mm (18")
ESPACE LIBRE DU POÊLE AU
CANADA
PLAFOND
1066mm (42") minimum
Flat Top & Step Top
2017 2018 2019 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.
Made in U.S.A. of US and
imported parts.
Fabriqué aux
États-Unis-d'Amérique par des
pièces d'origine américaine et
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
pièces importées.
R
Portland
Oregon USA
US
TESTED TO:/ TESTÉ À:
UL 1482-11 (R2015), ULC S627-00.
4300 ACC Series
VENT SPECIFICATIONS:
A
B
C
D
E
15.5 (394) 11.75 (298) 24.5 (622) 14.5 (368) 10 (255) 17.5 (445)
15.5 (394) 11.75 (298) 24.5 (584) 14.5 (368) 2 (51)
9 (229)
5.25 (133) 24.5 (622) 14.5 (368) 10 (255) 17.5 (445)
7.5 (191) 3.75 (95)
22 (559) 11.75 (298) 2 (51)
8.5 (216)
6 (152)
24.5 (622) 15 (381) 10 (254) 17.5 (445)
7.5 (191)
4 (102)
19 (229)
9 (229)
2 (51)
Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT** listed factory-built Class "A"
.
Six pouces (6 pouces) (152mm) de diamètre listé air isolé tuyau de raccordement à double paroi avec UL103 HT ** cotée Classe usine construite "A"
13 (330)
10 (255)
24 (610) 14.5 (368)
N/A
7.5 (191) 3.75 (95)
22 (584) 11.75 (298)
N/A
H
G G
H
G
43 MILLENIUM
43 STEP TOP
DISCOVERY III
FC7037-167H
Serial No. / N° de série
HF
SPÉCIFICATIONS DE LA VENTILATION:
MUR SIMPLE: De six (6
inches)
(152mm) de diamètre le connecteur de conduit de minimum
d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine UL103HT* de
Classe "A", adéquate pour usage avec les combustions solides, ou une cheminée de briques,
avec espaces libres référés.
MUR DOUBLE: De six
(6 inches)
(152mm) de diamètre, le connecteur du conduit d'air isolé pour
mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou une cheminée de
briques, avec espaces libres alloués.
MAISON MOBILE: Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk Metalbestos DS
ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les espaces libres pour mur double
comme mentionné ci-bas.
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:En Pouces & (millimètres)
NOTE: Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de l'entrée du conduit.
F
G
H
CONDUIT DU MUR DOUBLE
53.5 (1359) 12 (305)
Modèle au dessus en appartement
12 (305)
49.5 (1283)
12 (305)
Modèle au dessus en escalier
CONDUIT DU MUR DOUBLE
53.5 (1359)
12 (305)
Modèle au dessus en appartement
12 (305)
49.5 (1283)
5 (127)
Modèle au dessus en escalier
CONDUIT DU MUR DOUBLE
53.5 (1359)
N/A
Modèle au dessus en appartement
12 (305)
49.5 (1283)
N/A
Modèle au dessus en escalier
CONDUIT DU MUR DOUBLE
N/A
53.5 (1359)
12 (305)
Modèle au dessus en appartement
N/A
49.5 (1257)
5 (127)
Modèle au dessus en escalier
ALCOVE TOP VIEW /
VUE DU HAUT DE L'ALCÔVE
G
A
C
B
D
U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply
with 2015 particulate emission standards at 1.1 g/hr EPA Method 28
and 5G. Not approved for sale after May 15, 2020.
This wood heater needs periodic inspection and repair for proper operation.
Consult the owner's manual for further information. It is against federal regulations
to operate this wood heater in a manner inconsistent with the operating instructions
in the owner's manual.
Nº de série
BARCODE LABEL
Nom du
modèle
Nº du test
de
laboratoire
BACKWALL/SIDEWALL
et
MUR ARRIÈRE/MUR DE CÔTÉ
du rapport
A
B
C
D
CORNER INSTALLATION/
INSTALLATION DU COIN
E
F
E
F
ALCOVE SIDE VIEW /
VUE DE CÔTÉ DE L'ALCÔVE
G
A
B
Date
de fab.
7037-136L
13 Août, 2018