Do Not Install In A Mobile Home
READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION.
Position unit to comply with the minimum clearances to combustible materials. Minimum clear-
ances are shown in figures 1 and 2. It is recommended that no overhead cross members in the
ceiling or roof be cut. Reposition unit if necessary, being careful not to move closer than the
minimum clearances.
VENTING REQUIREMENTS
Use a "B" vent, masonry, or class "A"
chimney. Follow all manufacturers'
requirements and local building codes.
If you are using "B" vent utilize the
support box supplied with unit.
GAS LINE ATTACHMENT
The gas supply line must be installed at
the rear right side of the gas unit. This
supply line must be a minimum of 1/2",
black iron type pipe. A separate manual
shut off valve should always be used.
Check with local codes for its required
placement and valve type. In general it
must be placed within 6' of the appliance.
This valve is not provided.
Installation Instructions
8" "B" Vent
Support Box
Connector
Support Box
Page - 5
8" "B"-Vent
Framing
Sheet Rock
Support Box
3 - Sheet Metal Screws
8" Slip Connector
8" Middle Pipe
Section
BACK OF UNIT
GAS SHUT
OFF VALVE
Gas Zircon 34 4/1/20