Nicheless Underwater LED Lights | Owner's Manual
Section 8.
Use the troubleshooting information in the following table for suggestions.
Symptom
All lights fail to illuminate Lights are not reciev-
One or more lights are
dim, blinking or not
working
Colored lights out of
synch
Jandy
Pro Series Nicheless Underwater LED Lights are field servicable
®
and the cord and light body fixture should not be removed completely from
the conduit or pool. There should be enough cord supplied in the service
loop to remove light from wall fitting and lifted above water level for LED
light cartridge replacement. If there is not enough cord in service loop or it
cannot be accessed, pool water can be drained below light to access front
of light.
Troubleshooting
Problem
ing power
Poor connection or
improper wire gauge
Improper voltage
supply or poor con-
nection to the light
ENGLISH
Corrective Action
Check 120VAC power supply
into transformer. Check for
12VAC output at transformer.
Check or reset GFCI. Make
sure 120 volts has not been
used in the installation -
damage is assured and is NON
WARRANTY.
Separate each light and
independently wire 12V to the
single light only. Repeat this
process on each light. If junc-
tion box is being used, check
for proper connection of light
cord. Verify that the correct wire
guage is being used between
the transformer and junction
box.
Verify that proper wire connec-
tions are being achieved for
the lights that are out of synch.
Reset all the lights to white by
turning lights OFF for fi ve (5)
seconds, then turning ON
Page 15