English
Sampling
2 measurements/s for the digital display, 100ms for the
MAX function.
Degree of protection of the enclosure
IP 30 as per NF EN 60529
Maximum opening of jaws
∅ 28 mm
Dimensions
(L x l x H): 218 x 64 x 30 mm
Weight
280 g (with batteries)
5.3. Environment
5.3.1. Temperature
Operation:
0° C to 40° C, < 80 % RH
Storage:
-10° C to 60° C, < 70 % RH
5.3.2. EMC
Immunity:
as per EN 61326-1
Emissions:
as per EN 61326-1
5.4. To order
EMCheck LSMZ I
Instrument delivered in a box with:
1 operating manual
1 set of over-moulded silicone leads RD/BK
1 set of over-moulded test probes RD/BK
2 1.5V AAA or LR3 batteries
1 carrying bag
Accessories and spare parts
Set of 2 silicon leads with D4mm plugs
Set of 2 alligator clamps
2P+E socket tester
Carrying case 200x100x40 mm
APPENDIX: Reference conditions
Sine-wave signal:
- Frequency from 48 to 65Hz
- No DC component
Temperature 23° C ± 5° C, RH < 80%
External magnetic field < 40 A/m
No alternating magnetic field
Conductor being measured centred (in A)
Specifications given for values from 5 to 100% of each
range.
Note:
For a crest factor CF between 1.4 and 3 at full scale, add
1% to these specifications.
33
122010005
122150000
122150001
122150002
122150003
EmCheck LSMZ I