Installation For Round Surface Mount Electrical Boxes
AA/BB
GG x1
x2
FF x1
Pull supply wires out of the electrical box. Using machine screws (AA or BB), secure mounting strap (FF) to the electrical box. Ensure the side marked "FRONT" is
facing out. Remove protective paper from adhesive face of foam gasket (GG). Pull supply wires through the opening in gasket and adhere gasket to the mounting strap and outer
edge of round surface electrical box.
Pull supply wires out of the electrical box. Using machine screws (AA or BB), secure mounting strap (FF) to the electrical box. Ensure the side marked "FRONT" is facing out.
DD x1
Fixture must be properly grounded. Connect fixture ground wire to ground wire
in electrical box using wire nut (DD). These wires can be either green or bare
copper. Insert black supply lead into connector on black fixture wires and
white supply lead into connector on white fixture wires. Push excess wire
into electrical box.
NOTE: If eave mounting the fixture, position the sensor head with the adjustment
controls and drain holes facing downward to prevent water damage.
Test
The motion sensor on this fixture has a built in Dusk-to-Dawn sensor that automatically disables the motion sensor during daylight hours regardless of motion detection. All sensor
and light duration controls are located on the underside of the sensor head (PIR).
The motion sensor must be tested prior to starting. The TEST option is located on the TIMER MINUTES control knob. To test the fixture, switch the wall switch that
controls power to the fixture to the ON position and turn the control knob to the "TEST". During test mode, the lights will come on for 20 seconds, regardless of motion
detection or the time of day. The light will shut off automatically after 20 seconds. Leave the knob on "TEST" and test the sensitivity by crossing in the path of the sensor. The
light will come on only if it senses movement. Once movement stops, it will turn off in 5 seconds. The test is now complete.
Once the fixture has been tested, rotate the TIMER MINUTES control knob past Auto to the "timer settings" marked "1", "5" & "10" which indicate approximate minutes the light
stays on after motion is detected. The control knob can be positioned for a range of time settings between the "1" & "5", and "5" & "10" to increase or decrease light activation
when the PIR is triggered. It may be necessary to adjust the TIMER MINUTES knob several times until the desired ON time is achieved.
The control knob located on the adjacent side is marked SENSITIVITY, determines the range of motion detection. Rotating this knob to "Max." increases the distance of the
motion sensor up to 70 ft. Rotating the knob counterclockwise past "10Ft" lowers the distance to as close as 5 ft. It may be necessary to adjust the "SENSITIVITY" knob several
times. NOTE: A higher sensitivity level increases the chances of a false activation being triggered. For maximum range performance, allow the fixture to operate at any setting
(with power) for at least 48 hours.
The 180 degree coverage of the motion sensor is measured side to side. The sensor is more effective (side-to-side), rather than motion coming straight at it (in-and-out). Adjust
the motion sensor head so that it detects motion moving across the coverage area. The position of the sensor should not exceed 45° below horizontal. Do not aim the motion
sensor at any water, bushes or plants that may move in the wind, pedestrian traffic, moving cars, etc., as this will trigger the motion sensor. NOTE: If the sensor arm becomes
loose, it will not hold the sensor head at the proper angle. Readjust the sensor head and tighten the joint screw on the sensor arm.
To control the security light from inside the home, activate manual "ON" mode by toggling the wall light switch OFF and ON within 2 seconds. The security light will turn on and stay on
for approximately 8 hours, or until the Dusk-to-Dawn sensor detects light in the morning. Once the Dusk-to-Dawn sensor detects light, the manual "ON" mode will automatically go
back to its original settings of the AUTO motion sensor mode.
AA/BB
x2
FF x1
FF x1
EE x1
Position fixture over the mounting strap. Secure long machine screw (CC)
through the center hole of the wall plate and mounting strap. NOTE: Ensure
gasket (GG) properly seals gap between wall plate and electrical box to prevent
water seepage into electrical box. Restore power to the electrical box and
ensure that the light is functioning properly.
the silicone cap (EE) into the mounting screw opening to prevent water seepage
into the housing.
For recessed electrical boxes, use silicone adhesive caulking (not included) to
seal the gap between the wall plate and the mounting surface to prevent water
seepage into the electrical enclosure.
Timer
Installation For Recessed Electrical Boxes
Silicone
If the light is functioning properly, fit
Sensitivity
For Recessed
Electrical Boxes
Adjusting Sensor Head (PIR)
2

Publicité

loading

Ce manuel est également adapté pour:

Se1097-wh3-02lf0-g