FUNC-
BUTTON
SETTING BUTTON
TION
Time
Specify
Test: use this button during installation to
5m
15m
delay
check that the lighting has been correctly
5s
30m
for
connected.
load.
Time: specify the period when the lighting
1s
Test
will be switched off following the last detec-
tion.
Pulse: configure the sensor as a pulser (t = 1
sec. then 9 sec. off).
Meter
Specify
Specify the sensitivity of the PIR sensor. If it
detection
doubt, turn the setting fully to the +.
zone.
Lux
Configure
Eye: self-learning function for lux value
10 0
the light to
Lux: the higher the lux value the faster
switch with
50 0
5
the sensor will switch on. In the maximum
a load.
position the sensor will switch the light on
without regard to the lux value.
Watc h
Open /
Turn the Watch function on or off. See under
close LED
Watch function later in the manual.
alarm
function.
ON
OF F
Select
Holiday: the load will randomly switch on/off
Holiday
Panic
detection
in random intervals of 10min to 1 hour within
PIR only
HF only
method
a period of 4 hours.
PIR/HF
PIR+HF
And config-
Panic: the load will flash rapidly for a period
ure the
of 30 sec if movement is detected.
holiday or
panic
870060 only:
function.
HF/PIR: the load will switch on if the PIR or
the HF sensor detects movement. HF+PIR:
the load will switch on if the PIR AND the HF
sensor detect movement.HF only: the load
will switch on only if the HF sensor detects
movement. The PIR detection is switched off.
PIR only: the load will switch on only if the
PIR sensor detects movement. The HF detec-
tion is switched off.
Guarantee: 24 months after production date provided the product is used as instructed and not opened.
T +31 (0)88 002 3300
NL-3763 LB
EXTRA FUNCTIONS
Security function
The security function can be enabled by
setting the potentiometer lux value to
"Holiday".
This will cause the red LED to flash for 10
seconds and then illuminate for 10 sec-
onds to indicate that the detector is in se-
curity mode. Then the following will take
place irrespective of the standard lux,
movement and time conditions: every
day after the lux value drops below 50
lux the lighting will switch on for varying
lengths of time and at varying intervals
between 10 minutes and 4 hours.
In this period, if the lighting is switched
off, the red LEDs will move back and
forth. In this period, if the lighting is
switched on, all LEDs will flash simulta-
neously.
By resetting the lux potentiometer to the
correct lux value, the security function
will turn off again and the detector will
run in "automatic" mode again.
Watch function
The Watch function can be enabled by
setting the "Watch" potentiometer to On.
This will cause the 4 red LEDs to act in
two different ways.
1.
In standby. If the lighting is switched
off, the LEDs will move back and forth as
though a scan is being performed.
2. After detection has taken place, the
LEDs will simultaneously flash on/off. Af-
ter the set time has elapsed, it will return
to standby scan mode.
It is easy to disable the Watch function by
switching the "Watch" potentiometer to
off again.
Soest
www.klemko.nl
The Netherlands
APPROACH ROUTE (PIR)
CORNER MOUNTING
870004 only
info@klemko.nl
DIMENSIONS
870004 only
Wall mounting
Φ90mm
150mm
80mm
Ceiling mounting
Φ90mm
80mm
166mm
870060 only
Wall mounting
Φ90mm
150mm
80mm
Ceiling mounting
Φ90mm
80mm
166mm