Twilight switch LCI 803
Please read these instructions carefully and keep
for future reference. By purchasing this item, you
have chosen a high-quality GEV product. Please
read these operating instructions carefully to
ensure correct operation. Keep these instructions
in a safe place so that you can refer back to them
if necessary.
Operation
Twilight switch for retrofitting in lights. The twilight
switch controls lighting depending on ambient
brightness. If the level of brightness falls below
a certain value, the twilight switch automatically
switches the light ON; if this value is exceeded, it
switches the light OFF again.
Safety instructions
This device may only be installed by a
technician in accordance with the applicable
regulations.The electrical power supply and
the circuit protection must be switched off during the
entire installation process.
Please check that the connection cable is
disconnected!
Under no circumstances does the warranty cover
damage resulting from failure to observe these
instructions. Nor do we accept liability for any
indirect damage. Similarly, we can accept no liability
for any material damage
by mishandling or failure to observe the safety
instructions. In these cases, no warranty claim may
be made. In addition, for safety and compliance
reasons, you are not authorised to dismantle and/or
alter the house light in any way.
Installation position
The light sensor must be positioned so that the light
activated by the twilight switch does not shine directly
onto the light sensor.
Installation
The twilight switch LCI consists of two components:
the power section (Fig. A1), and the light sensor
(Fig. A2). The distance between the light sensor
and power section must not exceed 18 cm. Turn the
transparent sensor cap to remove it from the light
sensor (Fig. D1). The light sensor requires a 12 mm-
diameter opening; install the light sensor into the
opening from the inside (Fig. D2). Adjust the light
sensor so that it fits flush against the surface. Fasten
the light sensor using the transparent sensor cap
(Fig. D3). Mount the power section. Connect the
mains connection cable as shown in the wiring diagram
(Fig. B). Switch the circuit protection back on.
6
or bodily injury caused