WIRELESS DOUBLE TECHNOLOGY DETECTOR FOR OUTDOOR USE
GENERAL NOTICES AND WARNIGS - To be respected when the application is possibile.
Read carefully before using the appliances
Installation: all installation, maintenance and/or modification of these control units and their devices must be carried out by qualified technical staff. These operations can be
subject to specific technical Standards which must be complied with. The device is envisioned to be used exclusively inside buildings protected from exposure to very high and
very low temperatures as well as tampering by children and/or persons without common sense for the purpose and effects of the Civil Code.
Electrical connections: all electrical connections, without exception, must be made perfectly fixing all wires as envisioned in order to prevent accidental disconnection and
closing the containers and protection devices correctly. It is mandatory to disconnect all electric connections exceeding 25V in DC and AC before opening the containers of
functioning appliances.
External power supply: 230V CA 50 Hz - connect in compliance with country law regulations
Batteries Rechargeable accumulators and/or batteries of any type: these appliances use accumulators or batteries, which are potentially dangerous as they are pollutant,
therefore dangerous to the health of the public. Replace the accumulators and/or batteries exclusively with same models, position and connect them respecting the polarity
indicated in the instructions. It is mandatory to dispose of accumulators/waste batteries according to the Standards in force. This is also the case when the machines must be
scrapped. The accumulators/batteries must be previously removed, returning them to the appliance dealer or depositing them in the relevant containers made available by the
distribution network. If liquid should escape from the batteries or accumulators, use silicone gloves to protect the hands and prevent injury.
Liability: the manufacturer declines all liability consequent to incorrect installation and/or failure to use the devices supplied.
Warranty: the warranty is valid until the expiry written on the label inside the device in the terms envisioned by the Vienna Convention of 1980 regarding the International Sale of
Goods.
Copyright: all rights relative to this manual are the property of Silentron s.p.a. It is prohibited to partially or totally reproduce the texts and imaged herein, as is the introduction
into W.E.B. network and/or public distribution with any means.
Standard conformity: more of CE declaration, the products are in compliance with EN 50131-1 - environmental class 4 -
and they are declared of category I by the standard
300.220 - 1 (04/2006)
1. CONDITIONS FOR USE AND INSTALLATION CRITERIA:
Silent Dual Tech is a detector with double technology (PIR = passive infra-red detector + MW = microwave Doppler detector) developed to
indicate the approach of a human target or similar in movement in the protected area and it has been designed for use in outdoor areas with the
purpose of supplying an anti-approach pre-alarm in the case of intrusion. The use of the two detection technologies allows the appliance to
reduce the possibility of improper alarms, due to typical environmental factors linked to outdoor installation (movement of animals of all types,
movement of objects generated by meteorological phenomenon). Precise positioning and correct regulation of the appliance are fundamental for
this scope: in extreme cases it is possible to reduce these alarms even further by installing two opposite appliances in AND to protect the same
area (solution envisioned by the Silentron control panels).
Brackets and supports: the moveable joint code 5961 and the corner bracket code 8086 are useful accessories that can favour correct
positioning, which excludes the probability of movements in the protected area as much as possible.
2. FUNCTIONING
a) General features: the appliance functions with 3 AA alkaline batteries and transmits the alarm via radio, therefore connection wires are not
required. The PIR part of the appliance always functions and activates the MW part if intrusion is detected: the Doppler confirmation of the
existence of a moving mass in the area generates the alarm state. The detection sequence is displayed by the LED on the front of the
appliance, which changes colour (green-orange-red) through the various passages.
Block for the reduction of consumption: after every alarm the appliance is momentarily blocked. This is restored after 2 minutes with no
movement in the area. This is to reduce consumption in busy areas.
b) Adjustments: the PIR part can be adjusted in RANGE and in PULSE COUNTS, which constitutes an intervention delay. The MW is
adjusted in RANGE and DELAY, which is the minimum duration time of the movement detected at the end of the alarm.
c) Anti-removal protection: a relevant magnet, to be fixed to the wall in the point envisioned on the sliding bracket, allows anti-removal
protection. When the detector is correctly positioned on the bracket, the magnet closes a reed positioned inside the appliance: upward or
downward sliding and/or the detachment of the appliance from the wall causes a "tampering" alarm and the successive "test" state. In the case
of detector installation with swivel or angle brackets, the magnet must be correctly positioned in order to allow the TEST, as well as realising the
protection (see pictures).
d) Anti-opening protection: by opening the powered appliance, a relevant button controls the transmission of tampering independently from
the condition of the anti-removal magnet.
e) Appliance test conditions (TEST): Silent DualTech is in TEST mode when it is removed from its slide, behind which the magnet is located,
joined to the fixing surface: this causes the tampering alarm, it is therefore necessary to previously put the control panel in test mode. The test
state lasts 3 minutes successively to the correct re-positioning of the appliance and via LED displays all of the detections, annulling the block
after a first alarm.
Attention! Where it is not possible to install the anti-removal magnet, it must be held manually on the back of the appliance in the correct
position for at least 6 seconds with the appliance powered, in order to activate the control (confirmation beep). Successively it will be sufficient to
position the magnet in position and move it away for 1 second in order to activate the TEST state.
Attention! The appliance remains permanently in TEST when the anti-opening contact is open.
f) Supervision: SILENT Dual Tech transmits an operating status signal about every 40 minutes, which is managed by the SILENTRON
supervised control panels - see "supervision function" of the control panels used.
g) Low Battery signal: the appliance signals via radio to the control panel and locally using 5 beeps that the batteries must be replaced.