Connecting leads shall not be installed in the same conduit as the mains supply wiring,
communication cables or data cables.
Connecting leads and electric animal fence wires shall not cross above overhead
power or communication lines.
Crossings with overhead power lines shall be avoided wherever possible. If such a
crossing cannot be avoided it shall be made underneath the power line and as nearly
as possible at right angles to it.
If connecting leads and electric animal fence wires are installed near an overhead
power line, the clearances shall not be less than those shown in the table below.
Minimum clearances from power lines for electric animal fences
Power line voltage
≤1000 V
>1000 V to ≤33,000 V
>33,000 V
If connecting leads and electric animal fence wires are installed near an overhead
power line, their height above the ground shall not exceed 3 m (10'). This height
applies to either side of the orthogonal projection of the outermost conductors of the
power line on the ground surface, for a distance of:
2 m (6'6") for power lines operating at a nominal voltage not exceeding 1000 V.
15 m (50') for power lines operating at a nominal voltage exceeding 1000 V.
Electric animal fences intended for deterring birds, household pet containment or
training animals such as cows need only be supplied from low output energizers to
obtain satisfactory and safe performance.
In electric animal fences intended for deterring birds from roosting on buildings, no
electric fence wire shall be connected to the energizer earth electrode. A warning sign
shall be fitted to every point where persons may gain ready access to the conductors.
Clearance
3 m (10')
4 m (13')
8 m (27')