Chapter 4 Servicing the Device
6.
Carefully insert a new filter into the chassis. Use the wooden ruler as an aid to
guide the back edge of the filter to reach the end of the Velcro wall.
7.
Once the filter is fully inserted, push the wooden ruler against the filters surface
several times to insure that the filter is secure against the chassis wall.
Note:
filter will tear when you reinstall the fan.
8.
Insert the fan tray into the chassis.
9.
Lock the fan latch.
C
ONNECTING AND
C
ABLES
To connect a gigabit ethernet cable to a mini-GBIC connector transceiver port:
1.
Hold the cable clip firmly but gently between your thumb and forefinger, with
your thumb on top of the clip and your finger under the clip. (Do not depress the
clip ejector on top of the clip.)
2.
Slide the clip into the transceiver port until it clicks into place. Because the fit is
close, you may have to apply some force to insert the clip. To avoid clip breakage,
apply force evenly and gently.
To remove the cable from the transceiver port:
1.
Make sure the blue transceiver ejector is in a secured locked position (the blue
lever is flat against the front panel). Otherwise, when you attempt to remove the
cable, the transceiver might come out with the cable still attached.
2.
Hold the cable clip firmly but gently between your thumb and forefinger, with
your thumb on top of the clip and your finger under the clip.
44
Make sure that the filter is secure against the Velcro wall; otherwise the
D
ISCONNECTING
G
E
IGABIT
THERNET
User's Guide