3.4. Features

3.4.1. Setting the chlorine dosage

The chlorine dosage is the volume injected x times until the ORP measurement is equal to the ORP setpoint.
Possible settings : from
Default setting :
Recommended setting : according to the table below.
VOLUME OF THE POOL
1 m
3
10 m
3
30 m
3
50 m
3
60 m
3
100 m
3
120 m
3
1) Press and hold down the right-hand key, until the menu
2) Press the top or bottom key x times until the menu
3) Confirm by pressing the right-hand key.
4) Select a dosage with the top/bottom keys.
5) Confirm by pressing the right-hand key : the selected dosage freezes briefly.
6) Press on the left-hand key : the default display reappears.

3.4.2. Manual chlorine injection

Functions :
- Priming of the peristaltic pump and filling of semi-rigid pipes.
- Instant injection of chlorine, for a fixed period.
- Means of checking the correct operation of the peristaltic pump.
Possible settings : from
Possible settings:
then from
Default setting :
1) Press and hold down the right-hand key, until the menu
2) Confirm by pressing the right-hand key.
3) Select an injection duration with the top/bottom keys.
4) Confirm by pressing the right-hand key : the peristaltic is running, and the timer countdown is displayed in real time.
To stop the injection : press the left- or right-hand key.
5) Press on the left-hand key : the default display reappears.

3.4.3. Calibrating the ORP probe

I
To ensure an optimal ORP check, it is imperative that the ORP probe is calibrated :
- when first commissioning the equipment.
- at the start of each season when it is commissioned.
- each time the probe is replaced.
to
(i.e. from 10 to 990 mL, in steps of 10 mL).
If hypochlorite concentration of 11.4 %
(i.e. a chlorometric content of 36°)
(i.e. 20 mL)
(i.e. 170 mL)
(i.e. 500 mL)
(i.e. 850 mL)
(i.e. 990 mL)
to
(i.e. a duration of 1 s to 60 s, in steps of 1 s),
to
(i.e. a duration of 1 min 10 s to 9 min 50 s, in steps of 10 s).
DOSAGE
If hypochlorite concentration of 15 %
(i.e. a chlorometric content of 47° to 50°)
flashes.
flashes.
flashes.
(i.e. 10 mL)
(i.e. 100 mL)
(i.e. 300 mL)
(i.e. 500 mL)
(i.e. 600 mL)
(i.e. 800 mL)
(i.e. 990 mL)
6