HOSE REEL
Technical Data
Max. working pressure (bar)
Max. working pressure (psi)
Max. working temperatures (°)
Declarations
EU DECLARATION OF CONFORMITY
We, Desoutter GmbH, Edmund-Seng-Str. 3-5, 63477 Main-
tal, Germany, declare under our sole responsibility that the
product (with name, type and serial number, see front page)
is in conformity with the following Directive(s):
2006/42/EC (17/05/2006)
Harmonized standards applied:
EN ISO 12100:2010
Authorities can request relevant technical information from:
Pascal Roussy, R&D Manager, Ets Georges Renault, 38 rue
Bobby Sands, BP10273 44818 Saint Herblain, France
Saint-Herblain, 20/10/2019
Pascal ROUSSY
Signature of issuer
Regional Requirements
WARNING
This product can expose you to chemicals including
lead, which is known to the State of California to cause
cancer and birth defects or other reproductive harm. For
more information go to
Safety
DO NOT DISCARD - GIVE TO USER
WARNING Read all safety warnings, instructions, il-
lustrations and specifications provided with this
product.
Failure to follow all instructions listed below may result
in electric shock, fire, property damage and/or serious
injury.
Save all warnings and instructions for future refer-
ence.
WARNING All locally legislated safety rules regard-
ing installation, operation and maintenance shall be
respected at all times.
Statement of Use
• For professional use only.
SAR SERIES
15
217.5
-10 / +60°C
www.P65Warnings.ca.gov
• This product and its accessories must not be modified in
any way.
• Do not use this product if it has been damaged.
• If the product data or hazard warning signs on the prod-
uct cease to be legible or become detached, replace with-
out delay.
• The product must only be installed, operated and ser-
viced by qualified personnel in an industrial environ-
ment.
Product Specific Instructions
Installation
See figure 02.
Maximum installation height above floor level is 4 m.
• Choose a way of mounting to avoid excessive bending of
the hose against the outlet.
• Select a level surface on which to mount the reel.
• Ensure that suitable fixing bolts are used and that they
are secured. The bolts must reach a torque force of mini-
mum 900 N. When choosing mounting place, it should
be notified that the lifetime of the hose reel can be re-
duced by the influence of chemicals and strong UV or
heat radiation.
Connection
• The reel must be connected to the pipework system with
inlet hose only, minimum 1,0 m.
• Secure the hose on the support of the reel with cable ties
(not supplied).
• Check that the hose is not twisted or strained after con-
nection. A stop valve should be fitted on the pipe system
before the hose connection.
Disposal
• The disposal of this equipment must follow the legisla-
tion of the respective country.
• All damaged, badly worn or improperly functioning de-
vices MUST BE TAKEN OUT OF OPERATION.
Maintenance
WARNING Risk of personal injury! Before starting any op-
eration in the reel:
• Turn off the supply of air.
• Release the pressure.
• Follow local country environmental regulations for
safe handling and disposal of all components.
• Maintenance and repair work must be carried out by
qualified personnel using only original spare parts. Con-
tact the manufacturer or your nearest authorised dealer
for advice on technical service or if you require spare
parts.
• Inspection regarding hose, ratchet mechanism and
mounting on wall or ceiling should be accomplished at
least once a year .
© Rodcraft - 8956000973
5