Flush installation
Electrical Installation
The model stated on the front cover is rated at 120V AC,
60 Hz and uses a NEMA 5-15 plug to connect to a
dedicated 120 V microwave circuit.
Model
Connection
MB30WP
NEMA 5-15
Electrical Requirements:
a three prong grounded outlet
▯
120 V, 60 Hz, AC only
▯
15 Amp electrical supply with a fuse or a circuit
▯
breaker
This product must be connected to a supply circuit of the
proper voltage and frequency. Wire size must conform to
the requirements of the National Electric Code or the
prevailing local code for this rating. The power supply
cord and plug should be brought to a separate 20-amp
branch circuit single grounded outlet. The outlet box
should be located in the area behind the appliance (see
section Cabinet Dimensions). The outlet box and supply
circuit should be installed by a qualified electrician and
conform to the National Electrical Code or the prevailing
local code.
The voltage used must be the same as specified on the
data plate of this microwave oven. Using a higher voltage
is dangerous and may result in a fire or oven damage.
Using a lower voltage will cause slow cooking. The
manufacturer is not responsible for any damages
resulting from the use of the oven with any voltage other
than specified.
Circuit
Requirements
120 V,
15 Amps
60 Hz
Flush installation also requires:
two side cleats to be attached inside the cabinet
▯
frame, recessed from the front
a
/
" (8 mm) baseplate underneath the unit body.