Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

WARNING
• The charger is designed to charge and maintain 12V conventional lead-acid battery only. (VRLA), AGM, Pure Lead,
Gel and WET, not suitable for Li-ion batteries.
• We always recommend that you check the Battery Manufacturers specifications before using this charger
• Explosive gases may escape from the battery during charging. Provide ventilation to prevent flames and sparks.
• For indoor use. Do not expose charger to rain, snow or liquids.
• For charging lead-acid batteries ONLY (of the size & voltage indicated in the specifications table)
• Battery acid is corrosive. Rinse immediately with water if acid comes into contact with skin or eyes.
• The charger should be used on a flat surface.
• Never charge a frozen battery.
• Never charge a damaged battery.
• Never place the charger on the battery while charging.
• Be extra cautious to reduce risk of dropping a metal tool onto battery.
It might spark or short-circuit battery or other electrical part that may cause explosion.
• When working with a lead-acid battery, remove personal metal items such as rings, bracelets, necklaces, watches...
• NEVER smoke or allow a spark or flame in vicinity of battery or engine.
• Do not charge non-rechargeable batteries.
• In order to reduce risk of electric shock, unplug charger from AC outlet before doing any maintenance or cleaning.
Turn off controls will reduce risk.
• The kit is not supposed to be used by children or by people who are not able to understand the manual,
unless they are supervised by a responsible person who ensures the proper use of the kit.
OWNER'S MANUAL
8 AMP 12 VOLT BATTERY CHARGER
PLUS BATTERY MAINTAINER AND REJUVENATOR
Version française à la page
THIS MANUAL CONTAINS IMPORTANT SAFETY
AND OPERATING INSTRUCTIONS.
READ ENTIRE INSTRUCTION BEFORE USE.
MODEL: EWC12-148
USER'S MANUAL
1

Publicité

loading

Sommaire des Matières pour Enerwatt EWC12-148

  • Page 1 MODEL: EWC12-148 USER’S MANUAL OWNER’S MANUAL 8 AMP 12 VOLT BATTERY CHARGER PLUS BATTERY MAINTAINER AND REJUVENATOR Version française à la page THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS. READ ENTIRE INSTRUCTION BEFORE USE. WARNING • The charger is designed to charge and maintain 12V conventional lead-acid battery only. (VRLA), AGM, Pure Lead, Gel and WET, not suitable for Li-ion batteries.
  • Page 2 MODEL: EWC12-148 USER’S MANUAL MAIN FEATURES SMART CHARGE PLUS MAINTENANCE AND REJUVENATION • Easy to Use: Easy to operate and requires no technical experience. • Fully controlled by Microprocessor • Battery initial condition diagnosis • Enhanced battery rejuvenation (patented technology) •...
  • Page 3 MODEL: EWC12-148 USER’S MANUAL ECO MODE FOR ENERGY SAVING This battery charger has built in ultra-low power consumption circuit and operates with very high power efficiency. The charger will automatically go into ECO mode when battery is disconnected. Bulk/Masse Absorption...
  • Page 4 MODEL: EWC12-148 USER’S MANUAL TECHNICAL SPECIFICATIONS Model Number EWC12-148 Type Smart Input Voltage Range 100-120Vac Input Frequency 50/60Hz Output 8A @ 12V Start Voltage GEL-14.1V Charge Voltage AGM&WET-14.4V Pure Lead - 14,7 V Equalizing Voltage AGM&WET-15.5V Pure Lead -16.2V Float voltage 13.2V...
  • Page 5 MODEL: EWC12-148 USER’S MANUAL THE CHARGING PROCESS The charging stages and performance are as follows: ECO Mode If ac power is connected, and the battery is not connected, after 10 seconds, the charger will automatically go into ECO mode. • The Green LED is fast flashing indicates the ECO mode.
  • Page 6 MODEL: EWC12-148 USER’S MANUAL THE CHARGING PROCESS (CONTINUED) SMART CHARGING MODE • Analysis Mode ( Battery retention test Mode) ƒ The charging is interrupted for a short period for battery voltage measured ƒ If the battery voltage falls too quickly, the battery is probably faulty.
  • Page 7 MODEL: EWC12-148 USER’S MANUAL LED STATUS INIDICATOR TABLE STATUS DESCRIPTIONS 1. Press to select the charge rate 2. Green Maintenance charge mode is selected 3. Green Regular charge mode is selected 4. Green Maximum charge mode is selected STATUS DESCRIPTIONS 5.
  • Page 8 MODEL: EWC12-148 USER’S MANUAL TROUBLE SHOOTING TYPES OF INDICATION POSSIBLE CAUSES SUGGESTED SOLUTION PROBLEMS No Indicator Check AC connections and make sure Power Charger does not work? No AC power lights on. is switched ON. - Check DC connection between charger and battery and make sure they are not short circuiting.
  • Page 9 MODÈLE : EWC12-148 GUIDE D’UTILISATION MANUEL DU PROPRIÉTAIRE CHARGEUR DE BATTERIE DE 8 AMPÈRES 12 VOLTS AVEC FONCTIONS DE MAINTIEN DE LA TENSION ET DE RECONDITIONNEMENT CE GUIDE CONTIENT D’IMPORTANTES DIRECTIVES DE SÉCURITÉ ET DES INSTRUCTIONS D’UTILISATION. LIRE TOUTES LES INSTRUCTIONS AVANT D’UTILISER L’APPAREIL.
  • Page 10 MODÈLE : EWC12-148 GUIDE D’UTILISATION CARACTÉRISTIQUES PRINCIPALES CHARGEUR DE BATTERIE INTELLIGENT AVEC FONCTIONS DE MAINTIEN DE LA TENSION ET DE RECONDITIONNEMENT • Facile à utiliser : Facile à faire fonctionner et ne requiert pas d’expertise technique. • Entièrement commandé par un microprocesseur •...
  • Page 11 MODÈLE : EWC12-148 GUIDE D’UTILISATION MODE ECO POUR ÉCONOMISER L'ÉNERGIE Ce chargeur de batterie est doté d'un circuit à consommation énergétique ultra-faible intégré et fonctionne avec une grande efficacité énergétique. Le chargeur passe automatiquement au mode ECO si aucune batterie n'est connectée au chargeur; en mode ECO, la puissance absorbée est inférieure à...
  • Page 12 MODÈLE : EWC12-148 GUIDE D’UTILISATION CARACTÉRISTIQUES TECHNIQUES Numéro de modèle EWC12-148 Type Intelligent Plage de tension d'entrée du chargeur 100 à 120 V c.a. Fréquence d'entrée 50/60 Hz Sortie 8 A à 12 V Tension de démarrage GEL - 14,1 V Tension de charge AGM et à...
  • Page 13 MODÈLE : EWC12-148 GUIDE D’UTILISATION PROCESSUS DE CHARGE Les phases de charge et le rendement sont les suivants : MODE ECO Si le chargeur est branché sur l'alimentation électrique et qu'il n'est pas connecté à la batterie, il passe automatiquement au mode ECO après 10 secondes.
  • Page 14 MODÈLE : EWC12-148 GUIDE D’UTILISATION PROCESSUS DE CHARGE (SUITE) MODE DE CHARGE INTELLIGENT • Mode analyse (mode de test de rétention de la batterie) ƒ Le chargeur interrompt le processus pendant une courte période afin de mesurer la tension de la batterie.
  • Page 15 MODÈLE : EWC12-148 GUIDE D’UTILISATION TABLEAU DES ÉTATS INDIQUÉS PAR LES VOYANTS DEL ÉTAT DESCRIPTIONS 1. Appuyer pour sélectionner le type de taux de charge 2. Vert Allumé Sélection du mode de charge de maintien 3. Vert Allumé Sélection du mode de charge normal 4.
  • Page 16 MODÈLE : EWC12-148 GUIDE D’UTILISATION DÉPANNAGE CAUSES TYPES DE PROBLÈMES INDICATION SOLUTION SUGGÉRÉE POSSIBLES Aucun voyant Pas d’alimentation Vérifier le branchement sur l’alimentation électrique Le chargeur ne fonctionne pas? allumé électrique et s’assurer que l’appareil est sous tension. - Vérifier la connexion c.c. entre le chargeur et...