FCC NOTICE
CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment.
This device complies with Part 15 of the FCC Rules. Operation to the following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the device is operated in a commercial environment. This device generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference
to radio communications. Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
INDUSTRY CANADA STATEMENT
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. In addition,
this device complies with ICES-005 of the Industry Canada (IC) Regulations.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
ELECTRICAL CONNECTIONS
STEP 1:
For 120/277V applications make the following Electrical
Connections:
a. Connect the black luminaire lead to the supply
lead.
b. Connect the white luminaire lead to the neutral
supply lead.
c. Connect the green or green/yellow ground lead to
the green supply lead.
For 208/240V applications, make the following Electrical
Connections:
a. Connect Hot 1 supply lead to the black lead.
b. Connect Hot 2 supply lead to the white lead
c. Connect the green or green/yellow ground lead to the
supply ground lead.
STEP 2:
If dimming is being used, for E1/E2 connection, refer to Lutron
application note #142 (P/N 048162), Ecosystem bus Class 1 and
Class 2 listing at www.lutron.com for more information on wiring
options. If dimming is not being used, ensure to cap off the lead.
© 2020 Cree Lighting, A company of IDEAL INDUSTRIES. All rights reserved. For informational purposes only. Content
is subject to change. See www.creelighting.com/warranty for warranty and specifications. Cree
registered trademarks of Cree, Inc. SmartCast
Cree Lighting, A company of IDEAL INDUSTRIES.
3 of 3
, is a registered trademark and ZR14™, ZR22™ and ZR24™ are trademarks of
®
DRIVER ASSEMBLY
LINE OR
BLACK
HOT 1
NEUTRAL
WHITE
OR HOT 2
and the Cree logo are
®
E2 (VIOLET)
E1
(VIOLET/WHITE)
www.creelighting.com
LPN00678X0005A0_B