IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always
be followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l'alimentation avant
l'installation.
2.
This luminaire must be installed in accordance with the NEC or
your local electrical code. If you are not familiar with these codes
and requirements, consult a qualified electrician.
Ce produit doit être installé conformément à NEC ou votre code
électrique local. Si vous n'êtes pas familier avec ces codes et ces
exigences, veuillez contacter un électricien qualifié.
3.
Suitable for Damp Locations.
Convient aux emplacements humides.
4.
Access above ceiling required. Do not install insulation within
3 inches (76 mm) of any part of the luminaire.
Acces requis au-dessus du plafond. Ne pas mettre l'isolant a moins
de 76 mm (3 po) de toute partie du luminaire.
5.
Vapor barrier must be suitable for 90C.
Le pare-vapeur doit convenir pour 90 °C.
6.
No user serviceable parts.
Pieces non reparables par l'utilisateur.
7.
Inherently protected.
Protection inherente.
8.
Do not handle energized module with wet hands or when standing on
wet or damp surfaces, or in water
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
• The ZR-VDO/VRF Series of
recessed troffers is for non-
insulated ceiling applications
using T-Bar ceiling grid, drywall
grid adaptors, and suspended
mount.
• Designed for use in 120-277V 50-
60 Hz protected circuit (fuse box,
circuit breaker). Supply wire sized
as per NEC or governing code(s),
90C rated.
• Make sure to cap off all unused
leads.
TO INSTALL:
1
1 of 4
Specification Troffers with Emergency Driver and Removable Lens
• Lens and removable end cap may
shift during installation. Press
center of lens to engage magnet
strip and push the end cap against
the end panel to eliminate the gap
after installation.
• IMPORTANT: To avoid damage
to the lens or housing during
installation, make sure fixture is
supported near the centers of both
long sides of the housing when
lifting. Do not lift fixture from one
end only.
T-Bar Clips
Includes: ZR14-VDO/VRF, ZR22-VDO/VRF, ZR24-VDO/VRF
ZR14-VDO/VRF
ZR22-VDO/VRF
ZR24-VDO/VRF
NOTE: Fixtures ordered with -VDO are provided with a
factory installed integrated Lutron Vive wireless fixture
control with occupancy and daylight sensor. Fixtures
ordered with -VRF are provided with a factory installed
integrated Lutron Vive wireless fixture control.
NOTE: For set-up, programming, and troubleshooting
with a Vive system, please refer to the installation
instructions included with the Vive hub or at www.lutron.
com
T-Bar Clip Hole
ZR Series with
Lutron Vive Controls
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION
T- BAR CEILING MOUNTING
STEP 1:
Bring the ZR troffer into the T-bar
ceiling panel. See Figure 1 for location
of the T-bar clips on end panels of
troffer.
STEP 2:
Bend clips upward and rotate outward
to engage with T-bar support grid. See
Figure 2. Secure luminaire to grid in
compliance with state and local codes.
LPN00678X0008A0_B