1. GENERAL DESCRIPTION. TECHNICAL CHARACTERISTICS.
These installations are designed to reduce the pressure of a gas available in a distribution
installation to the pressure required at the working point.
General description of the series equipment:
Installation that just allows the use of a type of gas. It measures the flow by pressure.
STANDARD.
WITH ROTAMETER.
gas passage.
Installation that allows the use of two different gases. It measures the flow by pressure.
DOUBLE.
TECHNICAL
CHARACTERISTICS
Format
Gas
Inlet pressure
Outlet pressure
Flowrate
Inlet thread
Outlet thread
Equipment weight
Maximum
temperature of use
Minimum
temperature of use
According to UNE-EN 2503
TECHNICAL
CHARACTERISTICS
71700126
Format
Gas
Acetylene
Inlet pressure
Outlet pressure
Flowrate
Inlet thread
G3/8" RH
Outlet thread
G3/8" LH
Equipment weight
Maximum
temperature of use
Minimum
temperature of use
Segú According to UNE-EN 2503
WORKSTATIONS
Installation that just allows the use of a type of gas. It measures the flow by
Ref. 71600125 Ref. 71600725
Standard
Standard
Oxygen
Argon
25 bar
25 bar
10 bar
8 bar
3
30Nm
/h
28 l/min
G3/8" RH
G3/8" RH
G1/4" RH
G1/4" RH
1.42 Kg
1.42 Kg
60º C
60º C
-20ºC
-20ºC
Ref.
Ref.
71700701
Standard
Standard
Propane
1.5 bar
3 bar
1.5 bar
1.5 bar
3
3
5Nm
/h
4Nm
/h
G3/8" RH
G3/8" LH
1.46 Kg
1.46 Kg
60º C
60º C
-20ºC
-20ºC
Ref. 71600732
With rotameter
Argon
25 bar
2.5 bar
32 l/min
G3/8" RH
G1/4" RH
1.62 Kg
60º C
-20ºC
Ref. 71700801
Ref. 71700901
Double
Oxygen-Acetylene
Oxygen-Propane
25 / 1.5 bar
10 / 1.5 bar
3
30 / 5 Nm
/h
G3/8" RH
G1/4"RH / G3/8"LH G1/4"RH / G3/8"LH
2.58 Kg
60º C
-20ºC
EN
Ref. 71600800
Standard
Nitrogen
25 bar
10 bar
3
20Nm
/h
G3/8" RH
G1/4" RH
1.42 Kg
60º C
-20ºC
Ref.
71700851
Double
Double
Argón
25 / 3 bar
25 bar
10 / 1.5 bar
8 bar
3
30 / 4 Nm
/h
28 l/min.
G3/8" RH
G3/8"RH
G1/4"RH
2.58 Kg
2,58 Kg
60º C
60ºC
-20ºC
-20ºC
10