SAFETY
The equipment should only be repaired by the manufacturer or a qualifi ed electrician.
Before any cleaning, disconnect the computer from the mains.
Caution: before performing any intervention: disconnect the system from the water supply network or close the
water inlet valve.
Open the package and check that there are no dents or obvious damages to the appliance caused by transporta-
tion. In case of obvious defects or dents, do not install the appliance.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions con-
cerning the use of the appliance by a person responsible for their safety. Children must be supervised to assure
that they do not play with the machine.
This appliance generates a sound pressure level below 70dB.
WARNING
To reduce the risk associated with chocking:
- To reduce the risk associated with choking, do not allow children under 3 years of age to have access to
small parts during the installation of the product.
To reduce the risk associated with the ingestion of contaminants due to the use of microbiologically unsafe
water or of unknown quality:
- Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
of the system, before and after. Systems certifi ed for protozoan cyst reduction, may be used with disinfected
water containing fi lterable cysts. EPA Establishment Numb. 070595-MEX-001.
CAUTION:
To reduce the risk of property damage due to possible water leakage:
- Read and follow the instructions carefully before installation and usage of the fi lter cartridge.
- Protect from freezing by removing the fi lter cartridge when temperatures are expected to drop below 33° F
(1° C).
INSTALATION
The appliance must not be installed near water jets.
The appliance needs to be installed on a fl at surface.
The appliance must not be cleaned with water jets.
The appliance is compliant with the N climate class and must be installed in locations with a temperature bet-
ween +16°C and +32°C. Take all necessary precautions and do not install in locations with temperatures lower
than +3°C because if the water inside the product freezes, it seriously damages the water circuit.
Do not place any objects on top of the product.
Position the cooler in a clean, ventilated place, away from heat sources.
Leave a gap of at least 5cm on each side. This gap must be al least 25cm by the ventilation slots.
If the ventilations slots are covered, the cooling sytem cannot operate properly and this inevitably leads to
malfunctioning.
The system must be connected to the potable drinking water supply.
If the system includes a fi ltration system, ensure that all the fi lter elements are properly installed before making
any connection to the water supply.
Refer to the appropriate paragraph or instructions supplied with the fi lters for installation, maintenance and
expiry.
It is recommended to install a valve at the water input of the cooler, in order to isolate the system from the
water supply whenever it is necessary. When the customer is not able to service, it is recommended to install a
device that automatically stops water fl ow and isolates the product from the water circuit (our sales department
is available for further technical specifi cations).
No tools are required to connect the system to the drinking water tube. Connection is carried out easily and
within seconds, simply by inserting the tube directly into the rapid connection located on the back/side of the
product.
This product can be supplied with ¼" rapid connections if the connections are white (or beige).
In this case, do not use 6 mm metric tubes as these are not suitable.
Before connecting the water tube be sure that there are no traces of impurities in the inlet rapid connection. A
dust cap may be present, if so, it is necessary to remove it before water tube connection.
The incoming water pressure must be between 0.250 MPa e 0.500 MPa. The fl ow rate should not be less than 3
litres/minute.
CAUTION: If incoming water pressure is unknown, a "water pressure reducer" must be installed and set to
0.250-0.300MPa. Again, check that the pressure is maintained within this range even while water is dispensed,
or that variations do not exceed 0.10 MPa.
CAUTION: If an excessive drop in water pressure is detected during delivery, switch off the product imme-
diately and install it strictly in accordance with the above provisions.
Insuffi cient pressure causes damage to the pump in the water carbonation circuit, continuing intervention of
the electronic protection device and invalidation of the warranty.
Make sure that the power supply to the appliance is the same as the voltage indicated on the label on the side
of the appliance. The appliance must be grounded in compliance with applicable standards and laws. In case of
malfunctioning, grounding reduces the risk of electrical shocks.
Connect the appliance cable to a double-pole switch with a minimum of at least 3 mm distance between the
contacts, or using a plug which must still be accessible after installation.
Caution: non-compliance with the above conditions causes the compressor to overheat and break, leading to
immediate invalidation of the warranty.
USE
When you fi rst use the product, in order to remove any air inside the system, it is recommended to:
a. Open the water valve and wait a few minutes to make sure there are no water leakage.
b. Press the cold water button to let the air out. Release the button only when the water starts coming out.
c. Drain at least 30 litres of cold water and , if the system includes it, a few litres of the ambient water.
d. When you fi rst install the product, you will have to wait a few hours before dispensing cold water
It is possible to enable and disable cold water dispensing as well as temperature control by acting on the ther-
mostat.
During periods with low water collection it is better to set the thermostat at minimum.
During periods with high water collection it is better to set the thermostat at maximum. In this way the cooling
circuit is able to provide an ice reserve that would be necessary during the times of high operation of the
machine.
To modify the temperature just turn the regulation screw following the label placed near the thermostat. Hig-
her values means colder water.