Installation; Use; Maintenance And Cleaning; Electrical Connections - Vortice UVLOGIKA SYSTEM Notice D'emploi Et D'entretien

Uv-c lamp for sanitising surfaces
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH

Installation

Fig. 1÷15
Horizontal installation: 3÷7
Vertical installation: 8÷12
Note (fig. 13-14): The five grooves on the side of the device allow the lamp to be directed in five different
positions, depending on the specific installation requirements.
Note: When designing for use of more than one UVLOGIKA SYSTEM lamp in the same premises, consider
an optimal distance between one lamp and the next, as indicated in the following table:
Altezza
installazione
1 m
2 m
3 m
These configurations allow not to overlpa the effects of radiation of each lamp and to achieve an
uniform coverage of the premise.

Use

Use the switch connected during installation to switch the UVLOGIKA SYSTEM device on or off.
• WARNING: when designing the system, it is mandatory to provide at
least two automatic protection devices in series to prevent any risk of
accidental exposure to UV-C rays (i.e. presence detectors, timers, door
locks, lit signals; see connection diagram: Figure C).
If the optional accessories PIR SYSTEM (13049) and C PIR (12998) are connected, the device switches off as
soon as a person is detected in the room. After a pre-set period of time, the device switches on again if no person
is detected in the room. Please refer to the accessory instruction manuals for installation instructions and timer
adjustment.

Maintenance and cleaning

For maintenance or lamp replacement, contact an authorised VORTICE T echnical Service Centre.
The product does not require special cleaning. Remove dust from the lamp with a clean cloth or compressed air
after disconnecting the unit from the mains.

Electrical connections

To connect the device to the mains with PIR SYSTEM (13049) and C PIR (12998) or equivalent devices (figure
C).
Refer to diagram D for wiring multiple lamps on the ceiling.
Refer to diagram E for wiring two lamps on the wall.
16
Distanza tra
le lampade
1,8 m
2,4 m
4 m

Publicité

Table des Matières
loading

Table des Matières