4.3. Cleaning the induced draught housing and fan
• This housing is made accessible for cleaning by undoing the 4 nuts shown in Figure 3. (See arrows).
• Remove the induced draught motor by pulling it out.
• Now clean the flue gas passes, the induced draught fan and the flue tubes with a brush and an ash vacuum
cleaner.
• Then reassemble the components in reverse order.
CAUTION
Make sure that the seal is seated in the right position again. It is essential to replace defective seals.
• Make sure of the electrical connections on the fan motor and their correct positions.
Figure 3: Induced draught fan
1 Screw
2 Blower motor
3 Seal
CAUTION
Also the flue pipe must be cleaned.
8