2.5
Starting Up at the Solar-Log™
By switching-on the Solar-Log™, it will provide power to the Sensor Box Professional Plus. Afterwards, the
Sensor Box Professional Plus must be configured to the free RS485-port:
Open the dialogue
Configuration | Devices | Definition
Please refer to the Installation Manual in chapter "Connecting accessories", "Installation" and "Configu-
ring connected devices".
Select „M&T Sensor" as interface.
Carry out device detection.
The Sensor Box Professional Plus is integrated with the system in the same way as an inverter. The further
configuration could be handled with the Solar-Log™ web interface.
2.6 Technical Data
Sensor Box Professional Plus
Dimensions, weight
Housing
Protection mode
Operating temperature
Power supply
Supply Current
Communication Port
Protocol
Irradiance
Installation
Connection cable
Conformity
in the WEB menu of the Solar-Log™.
W/H/D in mm: 145/85/40, 360 g
Powder-coated aluminum
IP65
-20 °C to +70 °C
Via RS485 data cable from Solar-Log™ (10,5-28 V
Typical 10 mA
RS485
Solar-Log™, 9600 Baud, 8N1
Irradiance : ± 5 % (0 W/m
Cell-temperature: ± 1K (-20 °C to +70 °C) / ± 2 K (-40 °C to
+85 °C)
with screws on the substructure
4 pole, 3 m (10 feet), weather and uv resistant (LiY(St) 11 Y (4
x 0,14)
prolongable up to 50 m (165 feet)
CE :DIN EN-61000-6-1:2007 and DIN EN-61000-6-3:2007
DC
2
to 1400 W/m
2
)
),
7