Safety Notes
Gloves should be worn during installation to prevent
6
crushing and cutting injuries.
The shower system may only be used for bathing,
6
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pres-
6
sures.
Only dishwashers and washing machines certified
6
with the DVGW emblem may be connected to the
appliance connection valve without an additional
fuse. If no consumer is connected to the appliance
connection valve, it must be plugged.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
• The mixer can not used together with a continuous
flow water heater.
• The product is exclusively designed for drinking water!
4
English
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 33.
Dimensions (see page 34)
Flow diagram
(see page 34)
Rate of flow mixer
Rate of flow handshower
Rate of flow stop valve
Operation (see page 35)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Spare parts (see page 37)