Télécharger Imprimer la page

Baumer IR18.D08F-11170540 Mode D'emploi page 2

Publicité

Induktive Sensoren
Inductive sensors
Détecteurs inductifs
IR18.D08F-11170540
IR18.D08F-F60.UA1E.7BO
Induktive Analogsensoren
Inductive distance measuring sensors
Détecteurs inductifs avec sortie
analogique
11170540
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Canada
Italy
Baumer Inc.
Baumer Italia S.r.l.
CA-Burlington, ON L7M 4B9
IT-20090 Assago, MI
Phone +1 (1)905 335-8444
Phone +39 (0)2 45 70 60 65
China
Singapore
Baumer (China) Co., Ltd.
Baumer (Singapore) Pte. Ltd.
CN-201612 Shanghai
SG-339412 Singapore
Phone +86 (0)21 6768 7095
Phone +65 6396 4131
Denmark
Sweden
Baumer A/S
Baumer A/S
DK-8210 Aarhus V
SE-56133 Huskvarna
Phone +45 (0)8931 7611
Phone +46 (0)36 13 94 30
France
Switzerland
Baumer SAS
Baumer Electric AG
FR-74250 Fillinges
CH-8501 Frauenfeld
Phone +33 (0)450 392 466
Phone +41 (0)52 728 1313
Germany
United Kingdom
Baumer GmbH
Baumer Ltd.
DE-61169 Friedberg
GB-Watchfield, Swindon, SN6 8TZ
Phone +49 (0)6031 60 07 0
Phone +44 (0)1793 783 839
India
USA
Baumer India Private Limited
Baumer Ltd.
IN-411038 Pune
US-Southington, CT 06489
Phone +91 20 2528 6833/34
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
1/3
IR18.D08F-F60.UA1E.7BO
Abmessungen
Dimensions
Dimensions
M18 x 1
SW 24
3xLED
M12 x 1
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
Technische Daten
Einbauart
bündig
Messdistanz Sd
0 ... 8 mm
Empfindlichkeit
1,25 V/mm
Betriebsspannungsbereich
12 ... 36 VDC
+Vs
1)
Stromaufnahme max. (ohne
15 mA
Last)
Ausgangsschaltung
Spannungsaus-
gang
Ausgangssignal
0 ... 10 VDC
Lastwiderstand
> 4000 Ohm
Gehäusematerial
Messing verni-
ckelt
Arbeitstemperatur
-25 ... +75 °C
Schutzart
IP 67
Anzugsdrehmoment max.
40 Nm
Technische Änderungen vorbehalten
Technical specifications subject to change
Elektrischer Anschluss
BN (1)
+Vs
WH/GY (2/5)
teach-in
Analog U
BK (4)
output
Z
BU (3)
0 V
1)
Class 2, UL 1310, see FAQ
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
Technical data
mounting type
flush
measuring distance Sd
0 ... 8 mm
sensitivity
1,25 V/mm
voltage supply range +Vs
12 ... 36 VDC
1)
current consumption max.
15 mA
(no load)
output circuit
voltage output
output signal
0 ... 10 VDC
load resistance
> 4000 Ohm
housing material
brass nickel
plated
operating temperature
-25 ... +75 °C
protection class
IP 67
tightening torque max.
40 Nm
Sous réserve de modifications techniques
Connection diagram
Schéma de raccordement
teach-in
BN = Braun/brown/brun
BK = Schwarz/black/noir
2
WH = Weiss/white/blanc
3
BU = Blau/blue/bleu
0V
GY = Grau/gray/gris
Données techniques
Type de montage
noyé
Distance de mesure Sd
0 ... 8 mm
Sensibilité
1,25 V/mm
Plage de tension +Vs
12 ... 36 VDC
1)
Consommation max. (sans charge)
15 mA
Circuit de sortie
Sortie de tension
Signal de sortie
0 ... 10 VDC
Résistance de charge
> 4000 Ohm
Matériau du boîtier
Laiton nickelé
Température de fonctionnement
-25 ... +75 °C
Classe de protection
IP 67
Couple de serrage max.
40 Nm
+V
S
1
4
output
5 teach-in
26.9.2016

Publicité

loading