3.
Control Panel LEDs
light up, but no balls are
thrown.
4.
Balls thrown to wrong
places.
5.
Balls thrown at irregular
depths.
6.
Double throws or missed
throws.
7.
Random Place LED won't
turn on (p. 11).
8.
Er1 shown on display.
Ball LEDs flashing.
9.
Er2 shown on display.
Ball LEDs flashing.
10. Er3 shown on the
display.
A. Set the Ball/Min knob higher than zero.
B. Press Start/Stop to start ball delivery.
A. Are there rubber bands around the Deflector Plate and/or is
there a blue foam pad above it? If yes, remove those parts so
Deflector Plate can move freely. Those parts are used only during
transport.
B. Is Random on? If so, turn off (p. 11).
C. Unplug all 3 cable connections and then re-plug. Connect cable
to Control Panel last.
D. Check pins of Head Cable to be sure none are bent or missing.
There should be 15 pins.
E. If robot throws balls further to one side than the other, Deflector
Plate may need to be adjusted or replaced. Call your AMICUS
Service Center.
A. Check wheel clearance (p. 19).
B. Wheels worn. Replace all 3 wheels (p. 20).
C. Clean White Strip on Deflector Plate with isopropyl alcohol.
Replace if worn (p. 22).
A. Head height improperly adjusted (p. 8).
A. Exercise needs at least 2 Balls. If only 1 Ball LED is lit, add a sec-
ond Ball (p. 11).
A. Defective or oversized ball or foreign object jamming the lower
ball channel. Clear channel and test ball feed (p. 21).
B. Dirty or unwashed new balls are being used. Clear ball channel
of balls, then wash the balls to remove grit, rinse, and dry before
placing back into robot.
C. Is a foreign object or ball preventing the Ball Stirring Springs
from moving? If so, remove that foreign object or ball.
D. Was Black Knob tightened too much, denting the upper Ball Tube? Dis-
connect the head, and roll a ball up and down the Ball Tube to check if
it is obstructed. If so, call your AMICUS Service Center.
E. Bad Ball Feed Motor, broken gears or motor support. Call your
Amicus Service Center.
A. Is ball stuck among the 3 wheels? If so, turn off power, and then
remove that ball.
B. Bad Ball Throw Motor. Replace.
A. Overheated electronics. Switch off power and wait several min-
utes. If Er3 disappears, resume operations. If Er3 remains, call
your Amicus Service Center.
23