INSTALLATION
GB
The manufacturer will not accept any liability for damages
occurred during the appliance handling/transport and in-
stallation operations.
Carefully read the following installation instructions , before
installing the appliance.
Check that all the components are not damaged. In case of
damages, please contact your retailer and do not carry out
installation.
- Use an air exhaust pipe of the shortest possible length , with
a limited number of elbows, and made in a certified material.
- Avoid drastic section changes (recommended constant dia-
meter Ø 150 mm or similar surface).
- The manufacturer will not accept any liability for air capacity
or noise problems , should the above instructions be ignored.
The product will not be covered by our guarantee for problems
resulting from failure to comply with the aforementioned in-
structions.
All of the products have been designed with the possibility to
direct the air out-let towards the appliance rear side; in case
you choose this option , you will need to remove the no. 10
screws found in the suctioning unit support (fig. 3 ), pull the
suctioning unit out and rotate it in such a way as to direct the
air out-let nozzle towards the appliance rear side (fig. 4); then
refit the suctioning unit into place and tighten the screws pre-
viously removed.
With the help of the special drilling template (fig. 5A), please
drill the holes for the wall brackets.
The rear, lowest part of the appliance shall be placed at the
following minimum distance from the cook top:
SLTC93 minimum distance from the cook top: 495mm
SLTC94 - SLTC103 minimum distance from the cook top: 500mm
SLTC97 minimum distance from the cook top: 650mm