WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed within
42 inches (107 cm) of your washers water inlet. The faucets
MUST be 3/4 (1.9 cm) garden hose-type so inlet hoses can
be connected. Water pressure MUST be between 10 and 120
pounds per square inch. Your water department can advise
you of your water pressure. The hot water temperature
should be set to deliver water at 120° to 140°F (48°–60°C)
to provide proper Automatic Temperature Control (ATC)
performance.
NOTE: A water softener is recommended to reduce buildup of
scale inside the steam generator if the home water supply is
very hard.
DRAIN REQUIREMENTS
1. Drain capable of eliminating 17 gals (64.3 L)
per minute.
2. A standpipe diameter of 1 1/4 (3.18 cm) minimum.
3. The standpipe height above the floor should be:
Minimum height: 24 (61 cm)
Maximum height: 96 (244 cm)
BACK
NOTE: The drain hose attached to the washer can reach
a 58 (147 cm) high standpipe. For a higher standpipe,
contact an authorized parts distributor.
Installation Instructions
96" (8 ft.)
(244 cm)
Max.
24" (2 ft.)
(61 cm)
Min.
23
INSTALLING THE WASHER
1. Run some water from the hot and cold faucets to flush the
water lines and remove particles that might clog the inlet
hose and water valve screens.
2. Remove the inlet hoses from the packaging.
3. (90° elbow end) Ensure there is a rubber washer in the
90° elbow end of the HOT
and COLD hoses. Reinstall
the rubber washer into the
hose fitting if it has fallen out
during shipment. Carefully
connect the inlet hose
marked HOT to the outside
"H" outlet of the water valve.
Tighten by hand, then tighten
another 2/3 turn with pliers.
Carefully connect the other inlet hose to the inside "C" outlet
of the water valve. Tighten by hand; then tighten another
2/3 turn with pliers. Do not crossthread or over-tighten
these connections.
4. If inlet hose screen washers are not already inserted into
the inlet hoses, install them by inserting into the free ends
of the HOT and COLD inlet hoses with protruded side facing
the faucet.
H
5. Connect the inlet hose ends to the HOT and COLD
water faucets tightly by hand, then tighten another
2/3 turn with pliers. Turn the water on and check
for leaks.
6. Carefully move the washer to its final location. Gently rock
the washer into position. It is important not to damage the
rubber leveling legs when moving your washer to its final
location. Damaged legs can increase washer vibration. It
may be helpful to spray window cleaner on the floor to help
move your washer into its final position.
NOTE: To reduce vibration, ensure that all four rubber
leveling legs are firmly touching the floor. Push and pull
on the back right and then back left of your washer.
NOTE: Do not use the dispenser drawer or door to lift
the washer.
NOTE: If you are installing into a drain pan, you can use
a 24-inch long 2x4 to lever the washer into place.
C
Inlet Hose
Screen
Washers