Worksteps for both versions:
1.
Press the calibration button "Cal"- a for
approx. 3 sec. until "CAL1" appears
briefly in the display.
2.
Press the calibration button "Cal"- a
again.
"CALI1" will flash until "CAL2" is shown
in the display with an audible tone.
3.
Turn the measuring tool 180° about the
vertical axis so that the spirit level is still
pointing upwards but the display 7 is on
the opposite side to you.
4.
Wait for 4 seconds. Press the
calibration button "Cal"- a again.
"CALI2" will flash until "CAL3" is shown
in the display with an audible tone.
5.
Turn the measuring tool 180° about the
horizontal axis so that the spirit level is
pointing downwards but the display 7 is
on the side facing you.
6.
Wait for 4 seconds. Press the
calibration button "Cal"- a again.
"CALl3" will flash until "CAL4" is shown
in the display with an audible tone.
7.
Turn the measuring tool 180° about the
vertical axis so that the spirit level is still
pointing downwards but the display 7 is
on the opposite side to you.
8.
Press the calibration button "Cal"- a
again. "SUCC" then appears in the
display.
The measuring tool is now recalibrated for this
contact surface.
NOTE
If the measuring tool is not rotated about the
axis shown in the figures for steps 3, 5 and 7,
the calibration cannot be completed.
("SUCC" does not appear in the display.)
Maintenance and care
Observe the following instructions:
Handle the measuring instrument with
care and protect it from impacts,
vibrations and extreme temperatures.
When the measuring instrument is not
in use, keep it in the protective pouch.
If not used for a prolonged period, take the
batteries out of the measuring instrument.
Replace used batteries immediately.
Have the measuring instrument repaired
by qualified technicians and with original
spare parts only.
This ensures that the safety of the measu-
ring instrument is maintained.
ADL 60-P / ADL 120-P
15