Télécharger Imprimer la page

Haskel 8AG Serie Instructions De Fonctionnement Et D'entretien page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
6.4 Test:
Install gauge. Cycle drive at moderate speed until pressure stops rising. Record maximum pressure.
6.5 Analysis:
6.5.1 If the following pressures are achieved, the gas section condition should be considered satisfactory:
Model Number
8AGD -5
8AGD -14
8AGD -30
8AGD -60
If maximum pressure is less than the minimum, excessive leakage is occurring at the piston seal; and/or
the inlet check; and/or the outlet check.
6.5.2
Symptom Observing Gauge Pointer
A. Fast fall back from maximum.
B. Sluggish rise during pressure stroke.
If symptom B: DISCONNECT DRIVE AIR SO UNIT CANNOT CYCLE.* Apply 80 to 500 PSI clean and dry
air or gas to gas inlet port.
If leakage out vent tube is audible, piston seal is defective and/or gas barrel is scored.
If leakage out vent is barely detectable, inlet check is the problem. Disassemble and repair.
* CAUTION - NEVER CYCLE UNIT WITH PRESSURE APPLIED TO GAS INLET PORT WHEN GAUGE
IS IN OUTLET PORT. GAUGE WILL BE OVERPRESSURED.
Air Driven Gas Booster Compressor, 8" Drive AG Series • OM-12F
Pressure PSIG Minimum from Atmospheric Inlet
225
225
250
315
Repair
A. Outlet Check
B. Inlet Check and/or Piston Seal/Gas Barrel
12

Publicité

loading