Declaration Of Compliance; Gas Technical Data Table; Electrical Technical Data Table; Installation Of The Appliance - Lotus cooker CF4-8ET Instructions Pour L'installation Et L'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 2009/142 for the
gas part and with norm 2006/95/CE, 2004/108/CE for the electric part. The installation must be done observing the
norms in force particularly concerning room ventilation and discharging gas emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
DIMENS.
MODEL
CF4-8G
CF4-8GEM
CF4-8GEMS
DIMENS.
MODEL
cm
CF4-8ET
80x65x87
80x65x87
CF4-8ETS
CF4-8ET
80x65x87
CF4-8ETS
80x65x87
CFC4-8ET
80x65x87
CFC4-8ET
80x65x87
CF4-8G
80x65x87
CF4-8GEM
80x65x87
80x65x87
CF4-8GEMS
Installation, any transformations for other types of gas and starting can be done only by qualified personnel
according to the standards in force.
The gas systems, electrical connections and the rooms where the appliances are installed must be in accordance
with the standards in force in the country where they are installed; particularly, the appliance must be installed in a well
aired room, possibly under a suction hood to guarantee complete evacuation of the exhaust gases that are formed during
combustion; the necessary air for combustion is 2 m 3 /h per kW of installed power.
Caution: According to international directives, the appliance must be connected to the mains using a circuit breaker
which cuts off the flow of electricity in all poles. The distance between the disconnected poles must be at least 3 mm
Make sure that the air intake into the room where the appliance is installed is sufficient for an adequate change of air, as
specified by regulations in effect.
The appliances installed in buildings open to the public must satisfy the following requirements.
1)
Installation rules
The installation and maintenance of the appliance must be done according to the correct procedures and
regulation texts in use, particularly:
safety standards for the prevention of fire and panic.
Connection and installation of appliance, ventilation and exhaust removal systems, shall be done according to the
Manufacturer's instructions and by qualified technicians and according to the regulations in effect. The electric wiring
shall conform to the regulations in effect. All fire prevention codes shall be observed.
a)
General indications (Rules valid for G.B. only)
-
For all appliances:
Gas safety Regulations, 1984; Health and safety at Work Act, 1974 Codes of Practice, BS 8173, 1982, The
Building Regulations 1985; The Building Standards Regulations, 1981, the IEE Regulations and the by-laws of the
local Water Undertaking.
The local gas Region or LPG supplier and the local authority and the relevant recommendation of the British
Standards (latest editions) concerned.
GB

DECLARATION OF COMPLIANCE

GAS TECHNICAL DATA TABLE

Burner
Burner
cm
3,5 kW
5,5 kW
80x65x87
Nr. 2
80x65x87
Nr. 2
80x65x87
Nr. 2

ELECTRICAL TECHNICAL DATA TABLE

OVEN LAMP
TOTAL
kW
POWER Kw
0,015
0,015
0,015
0,015
0,015
0,015
0,015
0,015
0,015

INSTALLATION OF THE APPLIANCE

CHECKING FOR ADEQUATE VENTILATION

IE
IT
CH
Oven
Oven
Grill
4 kW
4 kW
Nr. 2
Nr. 1
Nr. 1
Nr. 2
/
/
Nr. 2
/
/
MAX.
ABSORB.
A
11,05
17,4
10,62
17,4
11,05
30,1
10,62
30,1
11,65
18,7
11,65
32
0,015
0,06
3,05
13,3
2,61
11,3
45
TOT. NOM.
Gas coupling
CAPACITY kW
22
18
18
POWER
POWER
SUPPLY
SUPPLY
CABLE mm²
400V~3N 50/60 Hz
5 x 2,5 mm²
400V~3N 50/60 Hz
5 x 2,5 mm²
230V~3 50/60 Hz
4 x 4 mm²
230V~3 50/60 Hz
4 x 4 mm²
400V~3N 50/60 Hz
5 x 2,5 mm²
230V~3 50/60 Hz
4 x 4 mm²
230V~ 50/60 Hz
3 x 1 mm²
230V~ 50/60 Hz
3 x 1,5 mm²
230V~ 50/60 Hz
3 x 1 mm²
ISO 7-1
½"G
½"G
½"G

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cf4-8etsCfc4-8etCf4-8gCf4-8gemCf4-8gems

Table des Matières