6.
Maintenance
- The power supply must not work in dusted ambient or in presence of chemical corrosive material.
- Do not clean the surface of the apparatus with aggressive products. Do not use oils or chemical solvents.
- Do not use the circuit breaker of the stabiliser as general switch of the user apparatus. This operation could damage the power
supply.
Do not lay things, books or something else on the top of the stabiliser, avoiding to place it near heat sources.
If you follow the above warnings the stabiliser will not need maintenance for several years. Meanwhile, it is suggested to periodically
open the unit cleaning the brush contact surface with a very light sandpaper or using a paintbrush. Never use and liquids or oils to
clean the contact surface or to improve the electrical contact.
7.
Technical data (can vary according to the specific model)
SINGLE PHASE
Input voltage
Output voltage
Output voltage accuracy
Frequency
Regulation speed
Load power factor
Load possible variation
Harmonic distortion
Full load efficiency
Ambient temperature
230V a.c. single phase, 400Vac three phase versions
0 - 250V a.c. max, 0:435Vac three phase versions
±1% (R10 models only)
50-60Hz
Usually between 4" to 8" for a complete turn
Any (from 0 to 1)
From 0 to 100%
0,2% or less
> 98%
-10°C +40°C