7 Dismantling
• Switch off the power.
• Drain the drainpipe thoroughly.
• Disconnect all supply and drain pipes.
If the lid of the GWDS has been opened moisten the rubber seal
with liquid soap or detergent before resealing it.
9 Faults
Make sure that the power is disconnected when carrying out any necessary repairs.
Fault
The motor starts spontaneously
The motor runs continuously or for a
long time
The motor will not start
The motor makes a noise but does not
run (does not pump)
The motor starts but stops spontane-
ously
GWDS
8 Technical details
Voltage
Current
Connections
Capacity of container
Maximum vertical lift
Maximum horizontal
displacement
Maximum liquid
temperature
Noise level
Protection
Weight
Pump capacity at
discharge height
of 4 metres
Possible cause
Taps are dripping
The non-return valve is faulty
The vertical lift is too high / There is too
much water flushing through / There are
too many bends in the installation
The equipment is not connected or the
power supply is faulty
The fuse has blown
The motor is faulty
The motor is damaged or the condenser
is faulty
The thermal protection system has been
activated because the waste water is too
hot.
      ENGLISH
:
12 V
24 V
120 V
:
28 A
14.5 A
6.5 A
: 1x ø 40 mm
1x ø 32 / 40 mm
1x ø 12 mm
1x ø 19 mm (drain)
: 3.5 litres
: 4 m
: 40 m
: 35˚C for a short period
: 40 dBA
: IP44
: 3.5 kg
: 44 litres/min
Solution
Check and repair the taps (replace the
gaskets)
Clean or replace the non-return valve
Check and change the installation
Connect the equipment or repair the
power supply
Mend the fault and replace the fuse
Consult a qualified engineer
Consult a qualified engineer
Allow the motor to cool off for an hour.
The thermal protection system will auto-
matically switch on.
110120.01
230 V
1.2 A
9