steps. Free steps will be marked "NOT
PROGRAMMED".
Select the step to be altered using the "UP"
and "DOWN" keys and confirm by
"ENTER". The display will list the following
entries:
CHANGE
CANCEL
INSERT BEFORE
INSERT AFTER
Change: press "ENTER" to confirm if you
wish to change the step currently selected.
Select the step with which you wish to replace
the currently selected step using the "UP"
and "DOWN" keys. Then confirm by
"ENTER".
The programmer will next display the
"COPY?" prompt. Press "ENTER" to
confirm the change or either press "MODE"
to cancel it.
Cancel: press "ENTER" to confirm that
you wish to cancel the currently selected
step. The programmer will next display the
"CANCEL?" prompt. Press "ENTER" to
delete the step or either press "MODE" to
cancel the change.
Warning! The "CANCEL" command does
not erase steps from the programmer but
only from the sequence associated to the
program selected. The steps cancelled can
be selected again, re-entered or changed as
desired.
Insert before and after: press "ENTER" to
confirm that you wish to insert a step before
or after the currently selected step. Select the
step to be inserted before or after using the
"UP" and "DOWN" keys and then press
"ENTER" to confirm.
To cancel the insertion, press "MODE".
TYPE
Move to the "TYPES" field using the "UP"
and "DOWN" keys.
Confirm your selection by pressing
"ENTER".
The display will list the following entries:
STRONG
MEDIUM
DELICATE
Select cycle type using the "UP" and
"DOWN" keys and press "ENTER" to
confirm. Program type selection is a just a
reminder for the user, which will be displayed
when it comes to program selection.
After program type selection press
"ENTER" to confirm and then "MODE" to
exit.
Attention! This selection does not alter
cycle execution in the least. It is only a
reminder for the user.
COPY FROM AND COPY TO
Move to the "COPY FROM" or "COPY
TO" field using the "UP" and "DOWN"
keys. Press "ENTER" to confirm.
Select the program you wish to copy from or
to using the "UP" and "DOWN" keys. Press
"ENTER" to confirm.
The programmer will next display the
"COPY?" prompt. Press "ENTER" to copy
between cycles or programs or press
"MODE" to cancel.
Whether you chose to confirm or cancel the
copy, press "MODE" to exit.
DESCRIPTION OF PROGRAMMABLE
FUNCTIONS
Machine parameters are those required to
effect marginal changes to the wash programs
without having to access cycle or step
programming.
These functions enable the user to skip
existing actions or add new ones in a wash
cycle. This does not alter the program features
in a radical manner, though.
The "MACHINE PARAMETERS" menu
is accessed as follows:
Open the washer door: all programming
actions must be performed with the door
open. The programing environment cannot
be accessed when the door is closed.
Hold down the "
MODE" key until the
"MACHINE PAR." reading appears. Press
"ENTER" to confirm.
The display will then read the following
items:
COOL
SPIN
PREWASH
DELAY START
BUZZER
HEATING
ENABLE
The various items are described below.
These functions affect only the currently
selected wash cycle and remain effective
until they are disabled.
Cooling
Cool: This function decides whether the
wash bath is to be cooled right before it is
drained off. As a rule, cooling is aimed to
prevent the garments from undergoing a
thermal shock as they go, for example, from
a 90°C wash step to ambient temperature
rinsing.
Select "COOL" using the "UP" and
"DOWN" keys.
Press "ENTER" to confirm.
Programs/cycles and their respective cooling
setting can be scrolled using the "UP" and
"DOWN" keys. Move to the desired cycle
and press "ENTER". Then choose between
"YES" and "NO" using the "UP" and
"DOWN" keys and press "ENTER" to
confirm.
Press "MODE" to exit.
Short spinning
Spin: This function allows to acknowledge
the standard-selected spinning, reduce it to
one-minute spinning or eliminate it
altogether. Select "SPIN" using the "UP"
and "DOWN" keys.
Press "ENTER" to confirm.
Programs/cycles and their respective reduced
spinning setting (enabled/disabled) can be
scrolled using the "UP" and "DOWN" keys.
20
Move to the desired cycle and press
"ENTER". Then again using the "UP" and
"DOWN" keys choose among:
NORMAL
REDUCED
NO SPINNING
Press "ENTER" to confirm.
Normal: standard final spinning is carried
out
Reduced: one-minute final spinning.
Spinning length is applied to the last spinning
speed. The acceleration ramp is never
reduced.
No spinning: final spinning is not carried
out.
Press "MODE" to exit.
No prewashing
Prewash: Generally speaking, all programs
include prewash. The purpose of this function
is actually to skip prewash, and is especially
useful when handling laundry that is not
heavily soiled.
Select "PREWASH" using the "UP" and
"DOWN" keys.
Press "ENTER" to confirm.
Programs/cycles and their respective
prewash setting can be scrolled using the
"UP" and "DOWN" keys. Move to the
desired cycle and press "ENTER". Then
choose between "YES" and "NO" using the
"UP" and "DOWN" keys and press
"ENTER" to confirm.
Press "MODE" to exit.
Deferred cycle start
Delay START:
This function defers
machine start to a maximum of 24 hours. As
soon as the scheduled time has elapsed the
machine starts automatically. When waiting
for the deferred start the machine reads the
countdown. If during the countdown the
"START" key is pressed, the machine
immediately starts the cycle that was
originally selected.
Select "DELAY START" using the "UP"
and "DOWN" keys.
Press "ENTER" to confirm.
The parameter status, i.e. either
"DISABLED" or "ENABLED" will appear.
Press "ENTER" to change the selection.
Use the "UP" and "DOWN" keys to make
your selection in minutes and/or hours and
then press "ENTER" to confirm.
Press "MODE" to exit.
As soon as the "START" key is pushed the
countdown starts and the display reads the
following message:
Start scheduled in:
countdown.(time remaining to the
beginning of the cycle)
BUZZER enabled/disabled
Buzzer: Each time a key is pressed the buzzer
gives out a short strong beep, which can be
eliminated by accessing this function.
Select "BUZZER" using the "UP" and
"DOWN" keys.
Press "ENTER" to confirm.
The parameter status, i.e. either