Orved VM Serie Mode D'emploi Et D'entretien page 67

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

VACUUM CHAMBER
PACKAGING MACHINES
7.4.6
WIRING DIAGRAMS
7.4.6.1
SINGLE-PHASE WIRING DIAGRAM
MULTIPLE P4/P8
VM12-VM16-VM18-VM18H-VM40N-VM53-VM53H
SP Power board
AC Cycle start
V C Sealbag valve
VS Softair function valve
VR Devacumation valve
VG Gas flushing valve
C V Vacuum chamber
PF1 Pump safety fuse
PF2 Sealing bar safety fuse
PF3 Power board safety fuse
PF4 Power board safety fuse
S Vacuum sensor
M Vacuum pump motor
I Main switch
SC Controller board
BS Sealing bar
TRS Sealing Transformer
7.4.6.2
THREE-PHASE WIRING DIAGRAM
VM18-VM18H-VM53-VM53H-VM19
VM20-VM30-VM1800-VM20 TANDEM
SP Power board
AC Cycle start
VS Softair function valve
CONT1 Pump remote control switch
V C Sealbag valve
B Devacumation valve
CONT2 Sealing remote control switch
VG Gas flushing valve
VA Evacuation valve
TRA Board transformer
C V Vacuum chamber
TSR1 Pump motor thermal cutout switch
TRS Sealing Transformer
PF1 Pump safety fuse
PF4 Power board safety fuse
PF2 Sealing bar safety fuse
PF5 Ceramic safety fuse
PF3 Power board safety fuse
SC Electronic controller board
S Vacuum sensor
M Vacuum pump
I Main switch
REPLACING FUSES
WARNING: This operation must be performed only by qualified personnel.
1) Disconnect the plug from the mains socket.
2) Remove the rear panel and remove the fusebox capsule by rotating it anticlockwise through half a turn and replace the burnt fuse with a new fuse
having identical features (See Technical Data Table page 42).
3) ATTENTION: In three-phase models, the ceramic fuse PF5 is not fixed on the power board but is positioned on the side of the remote control
switches inside the electric panel.
PF2
REV. 00 - Cod.: 1500154
PF3
PF1
PF4
PF5
67
MAINTENANCE
PF4
PF3
Operation and maintenance manual / Ed. 10 - 2005
GB
G B
GB
PF1
PF2

Publicité

Table des Matières
loading

Table des Matières