Overhead Mounting; Dmx-512 Connection - Luxibel LX103 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6.
Installation
Refer to the illustrations on page 2 of this manual.
6.1

Overhead mounting

Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable
norms.
The construction to which the device is attached should be able to support 10 times the weight of the
device for one hour without deformation.
The installation must always be secured with a secondary attachment e.g. a safety cable.
Never stand directly below the device when it is being mounted, removed or serviced. Have a
qualified technician check the device once a year and once before you bring it into service.
Install the device in a location with few passers-by and inaccessible to unauthorised persons.
Overhead mounting requires extensive experience: calculating workload limits, determining the
installation material to be used... Have the material and the device itself checked regularly. Do not
attempt to install the device yourself if you lack these qualifications as improper installation may
result in serious injuries.
For truss-mounting, use an appropriate clamp (not incl.) and fit an M10 bolt through the centre of
the (folded) bracket.
Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.
6.2

DMX-512 connection

When applicable, connect an XLR cable to the female 3-pin XLR output of a controller (not incl.) and
the other side to the male 3-pin XLR input of the LX103. Multiple LX103's can be linked through
serial linking. The linking cable should be a dual core, screened cable with XLR input and output
connectors.
Maximum recommended serial data link distance is 500 meters (1640 ft). Maximum recommended
number of fixtures on a serial data link is 32 fixtures.
A DMX terminator is recommended for installations where the DMX cable has to run a long distance
or is in an electrically noisy environment (e.g. discos). The terminator prevents corruption of the
digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120Ω
resistor between pins 2 and 3, which is then plugged into the XLR output socket of the last device in
the chain.
6.3
General
Make sure there is no flammable material within a 50cm radius of the device and there is sufficient
cooling.
Have a qualified electrician carry out the electrical connection.
All fixtures must be powered directly off a grounded switched circuit and cannot be run off a rheostat
or dimmer circuit, even if the rheostat or dimmer channel is used solely for 0% to 100% switch.
The installation has to be approved by an expert before the device is taken into service.
7.
Operation
Refer to the illustrations on page 2 of this manual.
7.1
Control Panel Navigation
Access the control panel functions using the four panel buttons located directly underneath the LCD
display.
button
function
<MENU>
used to access the menu or to return to a previous menu option
<ENTER>
used to select and store the current menu or option within the menu
<UP>
scrolls through the menu options in ascending order
<DOWN>
scrolls through the menu options in descending order
The control panel LCD shows the menu items you select from the menu map. When a menu function is
selected, the display will show immediately the first available option for the selected menu function. To
select a menu item, press <ENTER>.
V. 01 – 06/06/2012
LX103
5
©Velleman nv

Publicité

Table des Matières
loading

Table des Matières