Technical Data; Type Plate - Weidmüller Power Crimper Serie Notice D'instructions Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27

3.1 Technical data

Drive
Supply voltage
Power consumption
Fuse (mains filter module)
Protection type
Protection class
Operating pressure
Air consumption
Wire insertion length
Crimp length
Wire cross section
Crimp form
Cycle time
Ambient temperature
Operation
Storage / transport
Internal temperature in operation
Max. operating height
Humidity
Contamination level
Continuous sound pressure level
Dimensions (WxDxH)
Colour
Weight

3.2 Type plate

1
2
3
4
5
Figure 3.3 Type plate
2639590000/00/11.2018
Power Crimper 6.0
100 – 240 V AC; 50/60 Hz
I / protective earth conductor
13 mm (0.51") + crimping length
6 ... 18 mm (0.24 ...0.71")
0.5 ... 6.0 mm
-25 °C to +55 °C (brief +70 °C)
2000 m above sea level
50% at +40 °C (without condensation), 90% at +20 °C (without condensation)
165 x 405 x 240 mm (6.5" x 15.95" x 9.45")
1
Manufacturer
2
Model, type description
3
Serial number
4
Technical specifications
5
Year of construction
elektro-pneumatic
16 VA
2 x T2AH250V
IP20
5.5 bar
ca. 0,9 nl/cycle
(AWG 20 ... 10)
2
Quadro
1 s
+5 °C to 40 °C
max. 45 °C
2
< 70 dB (A)
RAL 2000
11.5 kg (25.35 lbs)
Device description
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Power crimper 6.02634310000

Table des Matières