Load controlled cooling fan
Cooling is carried out by convection and by forced air circulation by load-controlled fan.
The fan will normally be off and will be switched oN automatically at the following
loads:
• SAM-250-12 and SAM-450-12:
• SAM-800-12:
This will reduce energy consumption by the fan and will increase overall efficiency
principle of operation
Conversion of 12 VDC from the battery / other DC source to 115 VAC takes place in 2
stages. In the first stage, the 12 VDC is converted to high voltage DC (around 160 VDC)
using high frequency switching and Pulse Width Modulation (PWM) technique. In the
2nd stage, the 160V high voltage DC is converted to 115V, 60 Hz Modified Sine Wave AC.
(Note: 115V is the RMS value of the Modified Sine Wave AC voltage. The peak value of
the Modified Sine Wave AC voltage will be equal to the value of the above high voltage
of around 160V. See the fig 2.1 below)
modified Sine Waveform -
characteristics & comparison with pure Sine Waveform
Please refer to Fig 2.1 below which shows one cycle of Modified Sine Wave and
Pure Sine Wave for comparison.