OE 3004
TEMPERATURE
Range
0°C - 400°C
400°C - 1000°C
[1] If the temperature being measured is out of the range of 0°C - 1000°C, the display may show a reading; but
the measurement error may be large or the thermocouple may be damaged.
Note:
1. Use K type thermocouple.
2. Accuracy does not include error of the thermocouple probe.
3. Accuracy speci cation assumes ambient temperatures is stable to ± 1°C. For ambient temperatures changes of
±5°C, rated accuracy applies after 1 hour.

BATTERY TEST

Range
1.5V
9V
12V
DIODE AND CONTINUITY TEST
Range
DIGITAL MULTIMETER CAT. III
Resolution
1°C
Description
The working voltage of the battery will
be shown on the display so that the
quality of the battery can be judged.
Description
The approx. forward voltage drop of the
diode will be displayed.
The built-in buzzer will sound if the
resistance is less than about 30 .
The buzzer may or may not sound if the
resistance is between 30
The buzzer will not sound if the resistance is
more than 150 .
Accuracy
± (1.0% + 5)
± (2.5% + 10)
Open Circuit Voltage: about 2.8V
Test Current: about 1mA
Open Circuit Voltage: about 2.8V
and 150 .
Test current
environ 20mA
environ 5mA
environ 4mA
Test condition