very slowly into the pump. If the oil is added too quickly, it will
overflow and appear to be full.
CAUTION: Risk of unsafe operation. Overfilling with oil will cause
premature compressor failure. Do not overfill.
6. Replace dipstick.
7.The crank case (L) is full when the oil level reaches the halfway
point in the site glass.
CHAnGInG oIL
noTE: Pump oil contains substances that are regulated and must
be disposed of in accordance with local, state and federal laws
and regulations.
WARNING: Hot surfaces. Risk of burn. Aftercooler, pump head,
and surrounding parts are very hot, do not touch (see the Hot
Surfaces identified in Fig. 2). Allow compressor to cool prior to
servicing.
1. Ensure On/Off switch is in the OFF position.
2. Allow the unit to cool.
3. Remove air compressor plug from outlet.
4. Drain air tank.
5. Locate a suitable container under pump drain plug (L).
6. Remove the dipstick (K) from crank case.
7. Remove the oil drain plug (M).
8. Allow ample time for all oil to drain out. (Tilting the compressor
towards the drain plug will assist in draining.)
9. Install the oil drain plug.
10. Fill pump with ISO 100/SAE40, non-detergent, premium air
compressor oil.
11. Replace dipstick.
ACCESSORIES
Recommended accessories for use with your tool are available
for purchase from your local dealer or authorized service center.
If you need assistance in locating any accessory for your tool,
please contact Emglo Compressors, 701 East Joppa Road,
Baltimore, MD 21286 or call 1-888-88EMGLO (1-888-883-6456).
CAUTION: The use of any other accessory not recommended for
use with this tool could be hazardous. Use only accessories rated
equal to or higher than the rating of the air compressor.
SERVICE INFORMATION
Please have the following information available for all service calls:
Model Number ____________ Serial Number _________________
Date and Place of Purchase ______________________________
Repairs
To assure product SAFETY and RELIABILITY, repairs, maintenance
and adjustment should be performed by an authorized service
center or other qualified service personnel. Always use identical
replacement parts.
Full One Year Warranty
Emglo air compressors are warranted for one year from date of
purchase. We will repair, without charge, any defects due to faulty
materials or workmanship. For warranty repair information, call
1-888-88EMGLO (1-888-883-6456). This warranty does not apply
to accessories or damage caused where repairs have been made
or attempted by others. This warranty gives you specific legal
rights and you may have other rights which vary in certain states
or provinces.
19